5 - 6
Hardware Specifications
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4
Electra Elite IPK
S
ECTION
4
P
OWER
R
EQUIREMENTS
4.1
Power Supply Inputs
The AC input (P64-U( ) PSU) requirements for the Electra Elite IPK are listed
below:
AC input (P64-U( ) PSU)
H
117 Vac ± 10%
H
60 Hz ± 10%
H
Single Phase
H
7.5A circuit
H
A dedicated outlet, separately fused and grounded, is required.
4.2
Power Supply Consumption
The power consumption for the Electra Elite IPK system is listed in the table
below.
S
ECTION
5
E
NVIRONMENTAL
C
ONDITIONS
5.1
Temperature
H
Operating:
+32°F ~ +104°F (0°C ~ 40°C)
H
Recommended Long Term: +50°F ~ +90°F (10°C ~ 32.2°C)
5.2
Humidity
H
Operating:
10% ~ 90% noncondensing
Table 5-6 Power Consumption
KSU
Maximum
RMS
Current
Watts Used
(Idle)
Watts Used
(Maximum)
Basic KSU – B64-U( ) KSU
2.5 A
120
230
Basic KSU + Expansion KSU
5.0 A
240
460
Basic KSU + 2 Expansion KSUs
7.5 A
360
690
Summary of Contents for ElectraElite IPK
Page 2: ...GENERAL DESCRIPTION MANUAL INT 1024 IPK Document Revision 4 Release 4000 4500...
Page 3: ......
Page 5: ......
Page 8: ...Regulatory Information...
Page 25: ...Chapter 1 Introduction...
Page 54: ...Chapter 2 Features...
Page 103: ...Chapter 3 Equipment...
Page 124: ...Chapter 4 Installation Programming and Maintenance Overview...
Page 129: ...Chapter 5 Hardware Specifications...
Page 150: ...GENERAL DESCRIPTION MANUAL NEC Unified Solutions Inc Document Revision 4 Release 4000 4500...
Page 151: ......