1. Installing Internal Optional Devices
Express5800/E120e-M User's Guide
66
Chapter 2 Preparations
(2) When using optional RAID Controller (N8103-168)
For details, refer to the manual that comes with optional RAID Controller (N8103-168).
Important
•
You must avoid ESD damage to work with the procedure below. For details, refer
to
Chapter 2 (1.2 Anti-static Measures)
.
•
Do not let the system enter hibernation or standby mode while the RAID System
is configured..
Note
•
When installing an optional RAID Controller, run the BIOS Setup utility, select
Advanced
→
PCI Configuration
→
PCI Device Controller and Option ROM
Settings
, and make sure that the parameter of
PCI Slot
xx
Option ROM
(
xx
is PCI slot
number) is set to
Enabled
.
•
When connecting a RAID Controller, set the boot priority to 8th or higher in the
Boot
menu of the BIOS Setup utility. If the priority is 9th or lower, the configuration menu for
RAID Controllers cannot be launched.
Take the following procedure to install RAID Controller (N8103-168).
1. Refer to steps 1 to 3 in
Chapter 2 (1.3 Overview of Installation and Removal)
for preparations.
2. Remove the three screws from PCI riser
card. Hold both ends of PCI riser card, and
lift it straight to remove it.
3. Remove the two screws from RAID Controller,
and remove PCI bracket.
4. Attach the low-profile bracket to RAID Controller
with two screws you have removed in Step 3.
5. Align the terminal pins of RAID Controller with
the slot of PCI riser card, insert RAID Controller
into the slot completely and secure it with
screws.
Screw