NC2500S
1. Before Setting Up Your Projector
A-11
- Set the input voltage selection switch for the lamp power supply corresponding to the
voltage of the AC power supply used. Set it as follows:
AC power supply voltage used
Switch setting
200V-230V 200V
380V-415V 400V
Mounting terminals
The specifications of the cable mounting terminals of the lamp power supply unit are as
follows:
Power terminal (Gray)
JIS
IEC/EN
UL
CSA
Complying wire
(using solderless terminal)
14mm
2
14mm
2
AWG6
or
AWG8
AWG6 or
AWG8
Terminal screw
M6x15
Tightening torque
2.5 ~ 3.5Nm
Grounding terminal (Green/yellow)
JIS
IEC/EN
UL
CSA
Complying wire
(using solderless terminal)
14mm
2
14mm
2
AWG6
or
AWG8
AWG6 or
AWG8
Terminal screw
M6x15
Tightening torque
2.5 ~ 3.5Nm
Solderless terminal
Size of the solderless terminal compatible with the AC power cable mounting section of the
lamp power supply unit is as follows:
MIN
φ
6.1
MIN 9.5
MAX 11
MAX 13
Unit: mm
Input voltage selection switch