CHAPTER 6 16-BIT TIMER/EVENT COUNTER 00
User’s Manual U17446EJ3V1UD
97
Figure 6-10. Control Register Settings for Interval Timer Operation
(a) Capture/compare control register 00 (CRC00)
7
0
6
0
5
0
4
0
3
0
CRC002
0/1
CRC001
0/1
CRC000
0
CRC00
CR000 used as compare register
(b) Prescaler mode register 00 (PRM00)
ES110
0/1
ES100
0/1
ES010
0/1
ES000
0/1
3
0
2
0
PRM001
0/1
PRM000
0/1
PRM00
Selects count clock.
Setting invalid (setting “10” is prohibited.)
Setting invalid (setting “10” is prohibited.)
(c) 16-bit timer mode control register 00 (TMC00)
7
0
6
0
5
0
4
0
TMC003
1
TMC002
1
TMC001
0/1
OVF00
0
TMC00
Clears and starts on match between TM00 and CR000.
Remark
0/1: Setting 0 or 1 allows another function to be used simultaneously with the interval timer. See the
description of the respective control registers for details.
Figure 6-11. Interval Timer Configuration Diagram
16-bit timer capture/compare
register 000 (CR000)
16-bit timer counter 00
(TM00)
OVF00
Clear
circuit
INTTM000
f
XP
f
XP
/2
2
f
XP
/2
8
TI000/INTP0/P30
Selector
Noise
eliminator
f
XP
Note
Note
OVF00 is set to 1 only when 16-bit timer capture/compare register 000 (CR000) is set to FFFFH.