APPENDIX D LIST OF CAUTIONS
User’s Manual U17446EJ3V1UD
394
(12/19)
Chapter
Cl
assi
fi
cati
on
Function
Details of
Function
Cautions Page
To transmit data continuously, write the first transmit data (first byte) to the
TXB6 register. Be sure to check that the TXBF6 flag is “0”. If so, write the
next transmit data (second byte) to the TXB6 register. If data is written to the
TXB6 register while the TXBF6 flag is “1”, the transmit data cannot be
guaranteed.
p.189
ASIF6:
Asynchronous
serial interface
transmission
status register 6
To initialize the transmission unit upon completion of continuous transmission,
be sure to check that the TXSF6 flag is “0” after generation of the transmission
completion interrupt, and then execute initialization. If initialization is executed
while the TXSF6 flag is “1”, the transmit data cannot be guaranteed.
p.189
CKSR6:
Clock selection
register 6
Make sure POWER6 = 0 when rewriting TPS63 to TPS60.
p.190
Soft
Make sure that bit 6 (TXE6) and bit 5 (RXE6) of the ASIM6 register = 0 when
rewriting the MDL67 to MDL60 bits.
p.191
Hard
BRGC6: Baud
rate generator
control register 6
The baud rate is the output clock of the 8-bit counter divided by 2.
p.191
ASICL6 can be refreshed (the same value is written) by software during a
communication operation (when bit 7 (POWER6) and bit 6 (TXE6) of ASIM6
are 1 or when bit 7 (POWER6) and bit 5 (RXE6) of ASIM6 are 1), if 0 data has
been written to ASICL6 by SBRT6 and SBTT6.
p.192
In the case of an SBF reception error, return to SBF reception mode again.
The status of the SBRF6 flag will be held (1). For details on SBF reception
refer to (2) – (i) SBF reception in 11.4.2 Asynchronous serial interface (UART)
mode described later.
p.193
Before setting the SBRT6 bit to 1, make sure that bit 7 (POWER6) and bit 5
(RXE6) of ASIM6 = 1. Moreover, after setting the SBRT6 bit to 1, do not clear
the SBRT6 bit to 0 before the SBF reception ends (an interrupt request signal
is generated).
p.193
The read value of the SBRT6 bit is always 0. SBRT6 is automatically cleared
to 0 after SBF reception has been correctly completed.
p.193
Before setting the SBTT6 bit to 1, make sure that bit 7 (POWER6) and bit 6
(TXE6) of ASIM6 = 1. Moreover, after setting the SBTT6 bit to 1, do not clear
the SBTT6 bit to 0 before the SBF transmission ends (an interrupt request
signal is generated).
p.193
The read value of the SBTT6 bit is always 0. SBTT6 is automatically cleared
to 0 at the end of SBF transmission.
p.193
ASICL6:
Asynchronous
serial interface
control register 6
Before rewriting the DIR6 and TXDLV6 bits, clear the TXE6 and RXE6 bits to
0.
p.193
Chapter 1
1
Soft
Serial
interface
UART6
Bits 7, 6, and 5
(POWER6,
TXE6, and
RXE6) of ASIM6
Clear POWER6 to 0 after clearing TXE6 and RXE6 to 0 to set the operation
stop mode.
To start the operation, set POWER6 to 1, and then set TXE6 and RXE6 to 1.
p.195