CHAPTER 11 SERIAL INTERFACE UART6
Preliminary User’s Manual U16898EJ1V0UD
210
(4) Permissible baud rate range during reception
The permissible error from the baud rate at the transmission destination during reception is shown below.
Caution Make sure that the baud rate error during reception is within the permissible error range, by
using the calculation expression shown below.
Figure 11-26. Permissible Baud Rate Range During Reception
FL
1 data frame (11
×
FL)
FLmin
FLmax
Data frame length
of UART6
Start bit
Bit 0
Bit 1
Bit 7
Parity bit
Minimum permissible
data frame length
Maximum permissible
data frame length
Stop bit
Start bit
Bit 0
Bit 1
Bit 7
Parity bit
Latch timing
Stop bit
Start bit
Bit 0
Bit 1
Bit 7
Parity bit
Stop bit
As shown in Figure 11-26, the latch timing of the receive data is determined by the counter set by baud rate
generator control register 6 (BRGC6) after the start bit has been detected. If the last data (stop bit) meets this
latch timing, the data can be correctly received.
Assuming that 11-bit data is received, the theoretical values can be calculated as follows.
FL = (Brate)
−
1
Brate: Baud rate of UART6
k:
Set value of BRGC6
FL: 1-bit
data
length
Margin of latch timing: 2 clocks