6-28
CABLE TERMINATION
NWD-107460-02E
Installation
Procedure 6-6
N-P Connector used for ODU IF IN/OUT
(Straight: N435(R0))
1
Insertion of parts
The clamp nut, the washer and the gasket are inserted in the cable.
2
Remove of jacket of cable, insertion of parts,
(1) Remove 13 mm of jacket only.
(2)
The clamp1 is inserted as shown.
Note
Do not damage the braided wire.
Tools
•
knife, cutter, nipper, tweezers, file, measure,
clearance gauge, etc.
•
spanner, torque spanner; 16 mm
Tools
•
knife
•
cutter
•
measure, etc.
Outlines of parts
[Applicable cable: 5D-FB-E]
Cable jacket
Aluminum tape
Braided wire
Insulator
Center conductor
Washer
Clamp nut
Gasket
Clamp1
Clamp2
Connector body
Cable
Clamp nut
Washer
Gasket
13 mm
(Clamp1)