6-18
CABLE TERMINATION
NWD-107460-02E
Installation
4
Center conductor processing.
(1) Remove of the center conductor as shown.
(2) Chamfer the center conductor.
Note
Do not damage the center conductor.(burr, etc.)
5
Connector assembly
(1) The cable center conductor must be straight and aligned with the connector
inner contact. Insert the cable into the connector body until stopped; the center
conductor must be inserted into the connector inner contact fingers.
Tools
•
nipper
•
file, etc.
Center conductor
1 mm
5 mm ± 1
Center conductor
Connector body
Submission Prohibited