CABLE TERMINATION
6-23
Installation
NWD-107460-02E
6
Connector assembly
(1)
The cable center conductor must be straight and aligned with the connector
inner contact. Insert the cable into the connector body until stopped; the center
conductor must be inserted into the connector inner contact fingers. Tighten
the connection to the torque value of 60 to 80 lb-in (6.8 to 9.0 N·m).
(2)
The gap of the connector body and clamp nut is confirmed.
Gap: 0 to 0.5 mm
Notes
1
When inserting, do not put the chip which is braided wire inside the
central conductor and the connector body
2
Do not turn connector body, turn clamp nut attachment.
Tools
•
spanner (16 mm)
•
torque spanner (15 mm)
60-80 lb-in
(6.8-9.0 N·m)
0 - 0.5 mm
Submission Prohibited
NEC Internal Use Only