background image

 

IN001v1 

 

Page 1 of 2 

Start 

Collect

 and connect the Palm to the SID using the cable provided. 

The main screen shows the following information: 
 

Site 

 

 

 

Site Number 

Dump File 

 

Name of dmp file to be created   

 

 

 

 

upon Collection 

Main 

 

 

 

Main battery level 

Firmware

  

 

Firmware version 

Period

 

 

 

Survey binning interval 

Config

 

 

 

Current survey configuration 

Start 

 

 

 

Start Time/Date of survey 

End  

 

 

 

End Time/Date of survey 

Pilot

  

 

 

Time on Palm handheld 

 
To Collect the data from the SID, tap 

Collect

Tap 

Setup 

to enter the setup screen.  

 

Any data on the SID must be collected before entering the set-up menu. 

The 

Speed Limit 

can be set either by tapping on the dot-

ted line and writing on the graffiti pad, or by tapping on one 
of the shortcut icons. 
 
The 

Max Display Speed 

is the speed above the 

Speed 

Limit

 beyond which the SID will display bars and no speed 

information. It can be set in the same way as the 

Speed 

Limit

 
The 

Site Number 

can be set in the same way as the 

Speed Limit

. Changing the 

Site Number

 will not affect 

Collected data. 
 

 

 

If 

Synchronise Time & Date

 is ticked, the time on the SID 

will be set to that of the Palm. 

The options available in the set-up screen will vary depending on the configuration selected. 
The configurations available for the SID, and any additional options, are explained overleaf. 

Clever SID 

User Guide 