System parameter
Description
Default value
ip-rx-port
Which port the D-CALL/D-TECT IP should connect
to.
5001
ip-tx-timeout-sec
The timeout for messages being transmitted to
D-CALL/D-TECT IP devices.
5
log-in-retry-timeout-sec
Parameter control the timing of login and logout.
Determines for how long time the D-SERVER will
handle new login messages from an alarm receiver
as retransmissions of a previous login message.
120
log-out-all-timeout-sec
Parameter control the timing of login and logout.
Determines for how long time the D-SERVER sends
logout messages to all alarm receivers when the
D-SERVER is reloaded or restarted. If not all alarm
receivers are logged out when the D-SERVER is
restarted, the value of this parameter may need to
be increased.
10
log-out-forced-timeout-sec
Parameter control the timing of login and logout.
When the configuration is reloaded and the user
or group of a logged in D-TREX has been removed.
That D-TREX is logged out by force from the D-
SERVER. This parameter determines for how many
seconds such a forced log-out message is transmit-
ted by the D-SERVER.
10
log-out-retry-timeout-sec
Parameter control the timing of login and logout.
Determines for how long time the D-SERVER will
handle new logout messages from an alarm
receiver as retransmissions of a previous logout
message.
10
max-busy-time-sec
Parameter control the timing of status changes for
alarm receivers.
Determines the longest time that an alarm receiver
is allowed to be in “Busy” mode.
After this time has expired, the alarm receiver is
automatically set to “Idle” mode.
300
network-timeout-ms
Logging over Ethernet.
The longest time (milliseconds) allowed for trans-
mission of a log message over the Ethernet.
100
paging-cancel-send-count
Parameter control the timing of radio
transmissions.
Determines the total number of transmissions for
each paging cancellation message. If the D-SERVER
system contains four D-TECT units and the value of
this parameter is “4”, each D-TECT unit will send
the paging cancel message once. If not all alarm
receivers are reached by the alarm cancellation
messages, the value of this parameter may need to
be increased.
Note! Setting this value too high may slow down
the system.
7
paging-confirmed-warning-
enabled
If this parameter is set to “1”, then a text message
“Alarm already handled by...” is sent to any D-TREX
that confirms an alarm that has already been con-
firmed by someone else.
1