2.5.2 D-TECT IP connectors
1
2
3
4
4
Picture 18.
D-TECT IP connectors
No Denomination
1
AC IN
2
Ethernet (RJ45)
3
Compartment with reset button
4
Keyholes (x2) for wall mounting
Table 10.
D-TECT IP connector denominations
2.5.3 Power requirements
D-TECT IP can be power supplied either by a AC adaptor or by PoE (Power over Ether-
net) class 2, mode A & B.
The AC adaptor must supply voltage: 7.5V
DC
and current: 0.45A. Max power consump-
tion is 3.3W. For recommended AC adaptors, see "Appendix G Recommended NEAT
AC adaptors".
2.5.4 Mounting D-TECT IP units
D-TECT IP units must be installed in locations with good radio reception, for
example high up on corridor walls. A unit can be placed up or down but never hori-
zontal such as a lying on a table.
Picture 19.
Mounting the D-TECT IP
1. Insert the ethernet cable (and if required a DC cable).
2. The unit starts up.
3. Hang the unit in the slots on the backside.