NE41 09010-02 v3.0
D-SERVER
Technical Handbook
neat
14
Picture 10.
Mounting a D-TECT unit with the antennas up
2.2.5 Power requirements
The D-TECT can be power supplied either one-by-one with an AC adaptor or centrally
from a D-BOX (see below). When power supplied centrally only one cable is required
per D-TECT since the BUS provides the units with both power and a communications
bus.
The AC adaptor must supply voltage: 12V
DC
and current: 1,5A. The nominal power
comsumption is 3W.
2.3 Connecting D-TECT units to the D-SERVER
2.3.1 Connecting D-TECT units to a bus
1. Connect the first D-TECT unit to the bus.
Connect a network cable between the D-Box and the BUS connector on the D-TECT
unit.
2. Connect another D-TECT unit to the same bus.
Connect a network cable between the BUS connectors on the D-TECT units.
3. Repeat the previous step for each additional D-TECT unit you want to connect to
the same bus.
Picture 11.
Connecting D-TECTs to a bus using RJ11 cables