Turn the power back on to enter the settings into the EEROM and enable the Data
Scope Mode.
On remote models, the On Line light (green) blinks.
5.
Turn the power off.
6.
Set the DIP switches to the former settings.
DIP switch 1 must be Off to return the printer to the on-line mode.
7.
Turn the power back on.
The printer is on-line and can communicate with the host computer.
8.
Run a transaction from the host computer.
All commands and data sent from the host computer will be printed as Hex characters
as shown in the following illustration.
Exit the Data Scope Mode
1.
Turn the power off.
2.
Set the switches to the settings in the table.
Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
Switch 6
On
Off
Off
On
Off
Off
3.
Turn the power back on to enter the settings into the EEROM and disable the Data
Scope Mode.
On remote models, the On Line light (green) blinks.
4.
Turn the power off.
5.
Set the DIP switches to the former settings.
DIP switch 1 must be Off to return the printer to the on-line mode.
6.
Turn the power back on.
The printer is on-line and can communicate normally with the host computer.
Summary of Contents for 7193
Page 1: ...BD20 1440 A Issue B August 1998 NCR 7193 Thermal Receipt Printer Service Guide ...
Page 6: ...Contents 7193 Service Guide August 1998 x ...
Page 10: ...Chapter 1 About the 7193 Printer 7193 Service Guide August 1998 4 ...
Page 19: ...7193 Service Guide Chapter 2 Installing the Printer August 1998 13 Parallel Models ...
Page 22: ...Chapter 2 Installing the Printer 7193 Service Guide August 1998 16 ...
Page 24: ...Chapter 2 Installing the Printer 7193 Service Guide August 1998 18 ...
Page 26: ...Chapter 2 Installing the Printer 7193 Service Guide August 1998 20 ...
Page 38: ...Chapter 3 Diagnostics 7193 Service Guide August 1998 32 ...
Page 66: ...Appendix B Ordering Paper and Supplies 7193 Service Guide August 1998 60 ...
Page 78: ...Appendix E Commands 7193 Service Guide August 1998 72 ...
Page 83: ......