background image

stands/moves, security/ observation, the SIM card it works with, 
connected to the server/no/no gprs, receiver state, antenna short-
circuit/no antennas/visible satellites, the terminal temperature, gsm 
signal level, discrete state of inputs/outputs.

 

COM1 OLD_PASS, NEW_PASS 
Change of the password 

OLD_PASS – is a password set in the device. Factory default value 
1234. 
NEW-PASS – is a password that does not require replacing the old 
one. 
EXAMPLE: COM1 1234,4321  
After the command is executed the confirmation “NEW_PASS: 4321” 
will come

 

COM2 PASS,ID 
Change of device ID 

PASS – is a current password set in the device. Factory default value 
is1234. 
ID – is a number of the device, which takes a value from 1 to 65535. 
EXAMPLE: COM2 1234,8888 
After the command is executed the confirmation “NEW_ID: 8888” 
will come

 

COM3 PASS,IP,PORT 
Server setting 

PASS – is a current password set in the device. Factory default value 
is 1234. 
IP – IP address of the remote data collection server 
PORT – IP port of the remote data collection server 
EXAMPLE: COM3 1234,255.255.255.255,15000 
After the command is executed the confirmation “IP: 
255.255.255.255:15000” will come 

COM4 PASS,IN,OUT,MEM 
Security parameters 

PASS – is a current password set in the device. Factory default value 
is 1234. 
IN – is a time of disarming, which takes a value from 0 to 255 sec. 
OUT – is a time of arming, which takes a value from 0 to 255 sec. 
MEM – is a time of recovery of the query, a value from 0 to 255 min. 
EXAMPLE: COM4 1234,10,10,1 
After the command is executed the confirmation “NEW_TIMES: 
10,10,1” will come 

COM5 PASS,IP,PORT 
Remonte configuring 

PASS – is a current password set in the device. Factory default value 
is 1234. 
IP – IP address of the remote data collection server 
PORT – IP port of the remote data collection server 
EXAMPLE: COM5 1234,255.255.255.255,12500 
After the command is executed, the device will be reconnected to 
the specified address and send an SMS like: Remote config: 
255.255.255.255:12500 

COM6 PASS,MAP 
Location information 

PASS  – is a current password set in the device. Factory default value 
is 1234. 
MAP – Web-map. 0 – OpenStreet, 1 - Google. 
EXAMPLE: COM6 1234,0 
After the command is executed СМС message with location data a 
link to the specified map will come.

 

COM7 PASS,OUTNUM,ON/OFF 
Control of outputs 

PASS  – is a current password set in the device. Factory default value 
is1234. 
OUTNUM – is an output number. Available values (1,2,3 or 4) 
ON/OFF – is an output state after the execution. 1 – turn on, 0 turn 
off. 
EXAMPLE: COM7 1234,3,1 
After the command is executed the confirmation “OUT3: ON” will 
come

 

COM8 PASS,SW 
Automatic switching of SIM cards 

PASS – is a current password set in the device. Factory default value 
is 1234. 
SW – state. 0 – disable automatic switching of SIM cards, 1 - enable. 
EXAMPLE: COM8 1234,1 
After the command is executed the confirmation “Autoswitch SIM 
ON” will come 

COM9 PASS,MOVE,PARKING1,PARKING2 
Period of transmission of packages   

PASS – is a current password set in the device. Factory default value 
is 1234. 
MOVE – a period of distribution of packages when moving

 

(30 

seconds by default). 
PARKING1 - a period of distribution of packages while standing 
(range from 1 to 120 seconds by default). 
PARKING2 - a period of distribution of packages while standing 
(range from 1 to 120 seconds by default). 
EXAMPLE: COM9 60,120,300 
After the command is executed the confirmation 
“NEW_SEND_PACK: move 60, stop1 120, stop2 300” will come

 

COM10 PASS 
Disarming 

PASS – is a current password set in the device. Factory default value 
is 1234. 
EXAMPLE: COM10 1234 
After the command is executed the confirmation “DISARM XX:XX”, 
where XX:XX is a time of disarming, will come

 

COM11 PASS 
Arming 

PASS – is a current password set in the device. Factory default value 
is 1234. 
EXAMPLE: COM11 1234 
After the command is executed the confirmation ARM XX:XX, where 

Summary of Contents for GT-20 LITE

Page 1: ...NAVISET GT 20 PRO IRIDIUM WiFi BT NAVISET GT 20 LITE TRANSPORT MONITORING TERMINALS 2016 Version 5 1 25 01 2016 USER GUIDE Exclusive partner...

Page 2: ...cs SD card support announcement device additional black box Yes No Possible connection of the driver s display Yes No Support of WiFi Bluetooth IRIDIUM GLOBALSTAR Yes No RS232 interface 2pcs 1 piece G...

Page 3: ...speeds up cold start and increases accuracy HANDS FREE is a connection of any tablet PC based on Android to perform the functions of the driver s display loudspeaker communication and access to 3G and...

Page 4: ...of slots for SIM cards SD cards pcs 2 1 2 0 Number of SIM chips pcs optional 2 2 Voice interface for connection of loud speaker communication yes yes Bluetooth interface for the display optional yes n...

Page 5: ...n be replaced by STX3 or Gonets or Inmarsat in software The yellow color indicates the possible combinations of transmitters on the communication channels Combined transmitters can not operate simulta...

Page 6: ...advisable to set GSM as priority transmitter and 5 10 minutes for time of switching and testing of WiFi networks If WiFi appears from time to time it is better to let WiFi remain high priority and to...

Page 7: ...ed only upon request Before ordering it is necessary to agree on prices and date of execution of the order Other versions are available only by special order At the same time the appearance and locati...

Page 8: ...0 to 10 kHz IN4 0 36V analog digital input frequency square signal from 0 to 10 kHz IN5 0 36V analog digital input frequency square signal from 0 to 10 kHz IN6 0 36V analog digital input frequency sq...

Page 9: ...the input and the input 5 Engine hour indicator the input function is designed to count the car engine running time running time of the vehicle and to count the driver s working time When an input vo...

Page 10: ...CATOR Description of modes Is constantly on Data are being transmitted via a satellite Flashes once per second Initialization of the satellite channel Flashes 2 times per second for no longer than 2 s...

Page 11: ...the purpose of the contact See more detailed information in the specification for the handsfree 6 CONTROL AND CHANGE OF SETTINGS USING SMS COMMANDS To control and change the settings via SMS special...

Page 12: ...255 255 12500 After the command is executed the device will be reconnected to the specified address and send an SMS like Remote config 255 255 255 255 12500 COM6 PASS MAP Location information PASS is...

Page 13: ...NUMOP Change the operator in roaming PASS is a current password set in the device Factory default value is 1234 NUMOP an index of the operator of the terminal memory from 1 to 5 EXAMPLE COM17 1234 2...

Page 14: ...a straight section 0 off 1 on DELTA angle of leeway 0 360 MOVETIME record time on the move MINSPEEDANGLE minimum speed of the drawing on turns 0 250 ANGLE angle of the drawing on turns FEVOL filtratio...

Page 15: ...Glonass GPS module WiFi module 5 Software update The configurator is designed to work with NAVISET GT20 GT50 transport monitoring terminals When the configuration device is connected the only paramete...

Page 16: ...mouse over any element in the configurator description of the item and possible actions with is are displayed in this field Create a new configuration with the default parameters Open previously save...

Page 17: ...te connection to the device via GPRS It completely replaces the direct cable connection to the device without restriction of the CONFIGURATOR program functionality To establish the connection click se...

Page 18: ...require a specific APN Information about configuration upload to the cloud See the section of operation with the configurator CLOUD PANEL 7 2 RUNNING THE CONFIGURATOR PROGRAM 7 2 1 STATE MONITORING P...

Page 19: ...onfigured parameters For various modifications the data transmitters assigned to the channel are visually displayed on the panel of communication channels If in the section of Digital ports the satell...

Page 20: ...itter with the mouse up or down In the modification no 4 there is a possibility to choose combination of the IRIDIUM transmitter GlobalStar with the WiFi transmitter on the channel 1 or with GSM on th...

Page 21: ...the stationary mode If within the specified time the motion sensor is inactive the device switches to stationary mode Package recording period while driving specifies the time interval at which data p...

Page 22: ...ot displayed it means either the transmitter is not available or it is faulty IMEI GSM IMEI GSM of a transmitter It is displayed automatically when configuring the local device When the device is remo...

Page 23: ...t it is recommended to make a record according to the distance covered Historical records when parking If the object requires a long parking and at the same time it is necessary to periodically receiv...

Page 24: ...f points recording into memory is the time during which the coordinates are not recorded for any events Minimum number of satellites If the number of visible satellites is less than the specified valu...

Page 25: ...equency Input 1 8 For correct calculation of the frequency set the slider of the lower limit at the level of half the input signal amplitude discrete To connect digital sensors with two work position...

Page 26: ...flag can be processed by events for example dial specific numbers or to send an SMS with the specified text Repeated change to the active state drops the call if dialing of a number or a conversation...

Page 27: ...or flag if the key touches the contactor and removes it if the key is not on the contactor If the checkbox is selected when the key touches the contractor an extraordinary data packet with a key code...

Page 28: ...an choose the port the sensor is connected to in the section SETUP OF CONNECTION TO THE DEVICE and click the Apply button Then you can change the settings of the sensor using the regular software via...

Page 29: ...e In the CLIENT mode the NAVISET device receives data from the external device and records them to the register specified by the user or the external device reads its values from this register In this...

Page 30: ...ue specified by the user After the settings are set and reboot is completed a few parameters will be displayed in the Value column 7 2 7 THE ENERGY SAVING PANEL There are three options for the automat...

Page 31: ...th the announcement of the next stop along the route in other direction the bus stops must be announced in reversed order therefore different voice phrases are used Creating a list of coordinates of g...

Page 32: ...configuration of the device to the cloud service This function is very useful to remotely configure or to set up a large number of devices without a connection to a PC The function is available if the...

Page 33: ...ts that can be interconnected built in the logical chains independently changing static parameters All the logic is based on three main recommended algorithms 1 The linear algorithm as soon as all con...

Page 34: ...e on the battery 0 4 5 Security state Logic Active Inactive Alarm It occurs with the active signal on input with function standard alarm output when the security mode is on Logic Active Inactive Keys...

Page 35: ...ription Taken values Operation Start events processing Perform the actions of any of the created events even if the conditions for this event are not fulfilled ATTENTION It may lead to an infinite cyc...

Page 36: ...itch SW1 see Table 3 to allocate the RS232 interface for this port To check if a video camera is connected properly click PREVIEW If within 10 seconds a video frame appears the camera is connected cor...

Page 37: ...ck the box Run the fuel sensor s calibration wozard 9 FUEL SENSORSCOLEBRATION WIZARD The configurator allows you to make calibration of the fuel sensors connected to device in automatic and manual mod...

Page 38: ...In the table of values the sensor readings corresponding to the amount of fuel poured in the tank will appear Continue to pour fuel intill the tank is completely filled by pressing the Save button aft...

Page 39: ...in the calibration process will indicate how many liters have already been in the tank Specify the input that is connected to the fuel flow meter In the example in the picture the fuel flow meter is c...

Reviews: