stands/moves, security/ observation, the SIM card it works with,
connected to the server/no/no gprs, receiver state, antenna short-
circuit/no antennas/visible satellites, the terminal temperature, gsm
signal level, discrete state of inputs/outputs.
COM1 OLD_PASS, NEW_PASS
Change of the password
OLD_PASS – is a password set in the device. Factory default value
1234.
NEW-PASS – is a password that does not require replacing the old
one.
EXAMPLE: COM1 1234,4321
After the command is executed the confirmation “NEW_PASS: 4321”
will come
COM2 PASS,ID
Change of device ID
PASS – is a current password set in the device. Factory default value
is1234.
ID – is a number of the device, which takes a value from 1 to 65535.
EXAMPLE: COM2 1234,8888
After the command is executed the confirmation “NEW_ID: 8888”
will come
COM3 PASS,IP,PORT
Server setting
PASS – is a current password set in the device. Factory default value
is 1234.
IP – IP address of the remote data collection server
PORT – IP port of the remote data collection server
EXAMPLE: COM3 1234,255.255.255.255,15000
After the command is executed the confirmation “IP:
255.255.255.255:15000” will come
COM4 PASS,IN,OUT,MEM
Security parameters
PASS – is a current password set in the device. Factory default value
is 1234.
IN – is a time of disarming, which takes a value from 0 to 255 sec.
OUT – is a time of arming, which takes a value from 0 to 255 sec.
MEM – is a time of recovery of the query, a value from 0 to 255 min.
EXAMPLE: COM4 1234,10,10,1
After the command is executed the confirmation “NEW_TIMES:
10,10,1” will come
COM5 PASS,IP,PORT
Remonte configuring
PASS – is a current password set in the device. Factory default value
is 1234.
IP – IP address of the remote data collection server
PORT – IP port of the remote data collection server
EXAMPLE: COM5 1234,255.255.255.255,12500
After the command is executed, the device will be reconnected to
the specified address and send an SMS like: Remote config:
255.255.255.255:12500
COM6 PASS,MAP
Location information
PASS – is a current password set in the device. Factory default value
is 1234.
MAP – Web-map. 0 – OpenStreet, 1 - Google.
EXAMPLE: COM6 1234,0
After the command is executed СМС message with location data a
link to the specified map will come.
COM7 PASS,OUTNUM,ON/OFF
Control of outputs
PASS – is a current password set in the device. Factory default value
is1234.
OUTNUM – is an output number. Available values (1,2,3 or 4)
ON/OFF – is an output state after the execution. 1 – turn on, 0 turn
off.
EXAMPLE: COM7 1234,3,1
After the command is executed the confirmation “OUT3: ON” will
come
COM8 PASS,SW
Automatic switching of SIM cards
PASS – is a current password set in the device. Factory default value
is 1234.
SW – state. 0 – disable automatic switching of SIM cards, 1 - enable.
EXAMPLE: COM8 1234,1
After the command is executed the confirmation “Autoswitch SIM
ON” will come
COM9 PASS,MOVE,PARKING1,PARKING2
Period of transmission of packages
PASS – is a current password set in the device. Factory default value
is 1234.
MOVE – a period of distribution of packages when moving
(30
seconds by default).
PARKING1 - a period of distribution of packages while standing
(range from 1 to 120 seconds by default).
PARKING2 - a period of distribution of packages while standing
(range from 1 to 120 seconds by default).
EXAMPLE: COM9 60,120,300
After the command is executed the confirmation
“NEW_SEND_PACK: move 60, stop1 120, stop2 300” will come
COM10 PASS
Disarming
PASS – is a current password set in the device. Factory default value
is 1234.
EXAMPLE: COM10 1234
After the command is executed the confirmation “DISARM XX:XX”,
where XX:XX is a time of disarming, will come
COM11 PASS
Arming
PASS – is a current password set in the device. Factory default value
is 1234.
EXAMPLE: COM11 1234
After the command is executed the confirmation ARM XX:XX, where