[Trigger of SRS] -
function sets "the SPS" flag, this flag is transmitted in the structure of the protocol in
the block Status/Tracker parameters/Vehicle" - "Vehicle Condition." When going to the passive state, the flag is
removed. When the input is triggered, the extraordinary data packet is formed. If the input is triggered several
times, more data packets will be formed. This flag can be processed by events.
[Door limit switch] -
The function does not set any flags, processed only by events. If the device is on
SECURITY mode, the transition of the input to the active state generates an alarm event. Then It is processed on
a user's discretion.
REGISTER
– for all input types, regardless of the selected function, you can choose a record to the
internal data storage register. For analog, frequency, and counter inputsm the value recorded for the discrete
logic state is "1" or "0". Data from the register may be transmitted to the server in the form as they are, for this
purpose in the packet structure in the block «CAN/Modbus Data Registers" check the box next to the desired
register. The registers also can participate in events? For example, to compare values specified by the user.
1-Wire INTERFACE–
the input to connect the contactor of electronic keys. It is used to
identify the driver according to the TM electronic key (iButton).
[Keep the key code value when on the contactor]
– the function sets the "key on the
contactor" flag if the key touches the contactor, and removes it if the key is not on the contactor. If the
checkbox is selected, when the key touches the contractor, an extraordinary data packet with a key
code will be formed. The key code is transmitted in all subsequent packets while the key is on the
contactor.
[Keep iButton code value until the ignition is switched off]
- This function is available if the
"Control of ignition" function is selected for one of the inputs. After the key touches the contractor, its
code will be transmitted in each packet subject to the active input status with the "Control of ignition"
function before its transition into a passive mode.
Electronic key numbers can be stored in the device memory or on removable media such as
SD Card. The latter variant of storage is recommended if a large number of keys is used.
7.2.5. OUTPUTS
The setting of handlers for the outputs of the device does not have a certain visual version. All
outputs are controlled by events.
The sequence of actions caused by any source can turn on, turn off, invert and set pulse
sequence at the user's discretion.
The function of speed sensor simulation can be allocated any of the outputs. This function can
be used to transmit information about speed on the pulse input to the tachograph. To enable on the
panel, check the box "Speed sensor simulation " and select the output that will emulate the work of
this sensor from the drop-down list.
.
7.2.6. «DIGITAL PORTS» PANEL
The section of configurator is responsible for setting the parameters connected to the device via digital
interfaces RS232, RS485, and CAN BUS.