NCB Service Manual 117
Version 1.0
5.2.23
740Error
Error conditions and Check Items
Error
Description
E740
Abnormal
outdoor sensor
If an error (under 2.2kΩ or over 122.2kΩ) in the outdoor sensor is detected continuously for 3 seconds, The
system displays the error message E740 on the front panel. If this occurs, the boiler changes the control
mode from Reset Curve Mode to Normal Mode.
Check items
1.
Check the parameter setting (refer to page 47).
2.
Check the outdoor sensor