54 NCB Service Manual
Version 1.0
Component
Test performed
Display
Fan motor
Gradually increases the fan motor
speed from 0 rpm to full speed and
then decreases the speed to 0 rpm.
The current APS value and the current speed (rpm) are
displayed alternately at two second intervals.
Pump
Turns ON the pump for 10 sec and
then OFF for 5 sec. The cycle is
repeated five times for a total of 75
sec.
Displays ON or OFF based on the pump’s status.
3-way valve
Turn ON the 3-way valve when the
test mode opens. By pressing [+] or
[-] converts the valve’s state from
On -> Off or Off -> On.
When [+] or [-] is pressed, the condition toggles from On ->
Off or Off -> On.
Dual
venturi
Turn ON the dual venturi when the
test mode opens. By pressing [+] or
[-] converts the component’s state
from On -> Off or Off -> On.
When [+] or [-] is pressed, the condition toggles from On ->
Off or Off -> On.
<Error checking mode> returns to <Normal operation mode> after the automatic test is completed.
Summary of Contents for NCB-24LSWE
Page 16: ...14 NCB Service Manual Version 1 0 NCB 24 28 34LSWE...
Page 17: ...NCB Service Manual 15 Version 1 0 NCB 40LSWE...
Page 18: ...16 NCB Service Manual Version 1 0 NCB 40LSWE...
Page 60: ...58 NCB Service Manual Version 1 0 4 8 Electrical Diagnostic Contacts and Wiring Diagram...
Page 87: ...NCB Service Manual 85 Version 1 0 Scenario2...
Page 120: ...118 NCB Service Manual Version 1 0 5 2 24 782Error Error occurrence conditions and check items...
Page 140: ...138 NCB Service Manual Version 1 0 Memo...
Page 141: ...NCB Service Manual 139 Version 1 0 Memo...
Page 142: ...140 NCB Service Manual Version 1 0 Memo...