96 NCB Service Manual
Version 1.0
5.2.6
Error 030
Error occurrence conditions and check items
Error
Description
E030
Exhaust gas
temperature
error
If the overheat controller on the top of the exhaust duct is initiated, the system displays the heat
exchanger bimetal overheat message 030E (cleared manually) on the front panel.
The boiler switches into Lock-Out, and performs post-purge continuously and operates the pump.
Overheating controller operates when the temperature exceeds 110°C for 10 minutes or over.
1.
When the controller detects the exceeding temperature of 110°C for 10 minutes or more "E030" is
displayed and a post-purge will be performed.
→
Automatically cleared.
2.
When the controller detects the exceeding temperature of 60°C while performing post-purge.
→
Manually cleared.
3.
When the controller detects the exceeding temperature of 110°C for 10 seconds or over three times
or more after the error is automatically cleared.
→
Manually cleared.
Check items
1.
Check if the overheat controller operates normally.
2.
Check if the PCB works properly.
Summary of Contents for NCB-24LSWE
Page 16: ...14 NCB Service Manual Version 1 0 NCB 24 28 34LSWE...
Page 17: ...NCB Service Manual 15 Version 1 0 NCB 40LSWE...
Page 18: ...16 NCB Service Manual Version 1 0 NCB 40LSWE...
Page 60: ...58 NCB Service Manual Version 1 0 4 8 Electrical Diagnostic Contacts and Wiring Diagram...
Page 87: ...NCB Service Manual 85 Version 1 0 Scenario2...
Page 120: ...118 NCB Service Manual Version 1 0 5 2 24 782Error Error occurrence conditions and check items...
Page 140: ...138 NCB Service Manual Version 1 0 Memo...
Page 141: ...NCB Service Manual 139 Version 1 0 Memo...
Page 142: ...140 NCB Service Manual Version 1 0 Memo...