NCB Service Manual 107
Version 1.0
Testing method
Fault
Possible causes
Testing method
Defective sensor
Temperature sensor
connection fault
Check if the temperature sensor is open and if the connector is connected
properly.
Temperature sensor
fault
Check the resistance of the temperature sensor. The sensor is faulty if the
resistance is 30kΩ or higher)
Replace the temperature sensor if the resistance value is abnormal
(refer to page 62).
Check the temperature displayed on the front panel.
(refer to page 37).
Possible Issues
PCB fault
If the error condition continues after checking these items, replace the PCB.
<Heat exchanger input temperature sensor / connector>
Test to confirm if the hot water temperature sensor is open. Error: MΩ open circuit.
Summary of Contents for NCB-24LSWE
Page 16: ...14 NCB Service Manual Version 1 0 NCB 24 28 34LSWE...
Page 17: ...NCB Service Manual 15 Version 1 0 NCB 40LSWE...
Page 18: ...16 NCB Service Manual Version 1 0 NCB 40LSWE...
Page 60: ...58 NCB Service Manual Version 1 0 4 8 Electrical Diagnostic Contacts and Wiring Diagram...
Page 87: ...NCB Service Manual 85 Version 1 0 Scenario2...
Page 120: ...118 NCB Service Manual Version 1 0 5 2 24 782Error Error occurrence conditions and check items...
Page 140: ...138 NCB Service Manual Version 1 0 Memo...
Page 141: ...NCB Service Manual 139 Version 1 0 Memo...
Page 142: ...140 NCB Service Manual Version 1 0 Memo...