Detail: Indicates that the current rise rate to the associated channel is indicative of a short circuit condition.
This is a critical fault and will shut down the associated channel.
PFI_OpenFaultOverride
Tip Strip: Determines whether open-circuit faults are indicated
Detail: When set to
OVERRIDE
, the open circuit faults will be ignored and will not be indicated.
OpenCircuitFaults
Tip Strip: Lowside channel open-circuit fault
Detail: An open circuit fault is detected when the current never reaches the requested current level specified
by the lowest current setpoint in Phase 1 or Phase 2 of the PFI 1-4 tab. This is not a critical fault. If an open
circuit fault is indicated, pulses will continue to be delivered to the channel as normal. The open circuit fault
indicator is updated at the end of each delivered command pulse.
PFI Output Config
Tip Strip: Opens PFI Output Mode configuration window
that allows users to change the mode of output operation for each of the
PFI channels. Each channel is normally configured to drive a PFI injector, but each can be configured as
either an active high or active low digital output.
Summary of Contents for NI DIDS-2103
Page 11: ...NI DIDS 2100 Series User Manual National Instruments 11 3 2 Software...
Page 32: ...32 ni com NI DIDS 2100 Series User Manual...
Page 40: ...40 ni com NI DIDS 2100 Series User Manual 3 3 Hardware...
Page 44: ...44 ni com NI DIDS 2100 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 174: ...174 ni com NI DIDS 2100 Series User Manual Aux PWX 2 4 See above descriptions...
Page 210: ...210 ni com NI DIDS 2100 Series User Manual 12 Connecting Port Fuel Injectors to the PFI Driver...
Page 214: ...214 ni com NI DIDS 2100 Series User Manual 16 9066 RS 232 Serial Connector to TDK Power Supply...
Page 216: ...216 ni com NI DIDS 2100 Series User Manual 8 Important Information...
Page 223: ...NI DIDS 2100 Series User Manual National Instruments 223...