![background image](http://html1.mh-extra.com/html/national-instruments/ni-dids-2103/ni-dids-2103_user-manual_3423830026.webp)
26 | ni.com | NI DIDS-2100 Series User Manual
This will cause SCM to search the network for a National Instruments RT controller, such as the
cRIO-9066
.
If the DI Driver System controller is discovered, take note of the discovered IP address. The Windows PC
used to interface with the system must have a similar IP address and Subnet mask as the system controller,
but the IP address must be different in the last address number. The Subnet mask should be 255.255.255.0.
section to see how to change the IP address of the Windows PC.
The
Real-Time Backup and Restore
dialog may be exited by selecting the
Exit
button.
4. Check the System Controller Ethernet Cable Connection
If the green and amber LEDs directly under the controller Ethernet port are not active or blinking, then there
is no physical connection to a network router or PC, or there is no power to the controller. Please diagnose
the Ethernet cable connection or controller power problem.
If none of the above suggestions resolve the system connection problem, follow the
instructions below to reset the system controller network interface settings to DHCP.
cRIO-9066 Controller
To manually reset the network settings of the cRIO-9066 controller included with DI Driver Systems, follow the steps
below:
1. Power up the cRIO-9066 controller.
2. Press and hold the
reset
button for greater than 5 seconds. Release the
reset
button. This will cause the
controller to reboot into safe mode and the DI Driver System software will not load. This is indicated by the amber
Status
LED blinking 3 times.
Summary of Contents for NI DIDS-2103
Page 11: ...NI DIDS 2100 Series User Manual National Instruments 11 3 2 Software...
Page 32: ...32 ni com NI DIDS 2100 Series User Manual...
Page 40: ...40 ni com NI DIDS 2100 Series User Manual 3 3 Hardware...
Page 44: ...44 ni com NI DIDS 2100 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 174: ...174 ni com NI DIDS 2100 Series User Manual Aux PWX 2 4 See above descriptions...
Page 210: ...210 ni com NI DIDS 2100 Series User Manual 12 Connecting Port Fuel Injectors to the PFI Driver...
Page 214: ...214 ni com NI DIDS 2100 Series User Manual 16 9066 RS 232 Serial Connector to TDK Power Supply...
Page 216: ...216 ni com NI DIDS 2100 Series User Manual 8 Important Information...
Page 223: ...NI DIDS 2100 Series User Manual National Instruments 223...