62 | ni.com | NI DIDS-2100 Series User Manual
Detail: Operating mode applied to the associated DI Driver module.
Each DI Driver module can be independently assigned a mode of operation which will apply to all channels
of the associated DI Driver module. The
refers to the mode of sending injection commands to the
channels of the associated module. It is still necessary to configure the current and voltage drive profile via
this
Direct Mode:
The DI Driver module channels are commanded directly by external digital inputs of the NI
9411 modules. The digital input which commands each channel can be configured via the
window. The digital input level which commands the DI Driver channel
ON
is configured via the
Invert
buttons of the
window. The duration of the injection command is determined by the direct
duration of the digital input. The maximum duration allowed is 5 msec. If longer durations are required,
consult with your National Instruments sales engineer or support team.
Calibration Mode:
Calibration mode is for the purpose doing injector flow calibrations. Calibration mode
is configured via the
window for a specified number of injection events, command
duration and command period. Only one channel of each module may be enabled for
Calibration mode
. If
more than one channel is enabled, then commands will not be delivered.
Triggered Multi-Pulse (TMP) Mode:
The DI Driver module channels are commanded by a specified
sequence of pulses and triggered by an external digital rising or falling edge to the assigned digital input
channel. The pulse sequence is configured via the
window. The
external trigger channel is assigned via the
window.
Engine Position Tracking (EPT) Mode:
The DI Driver module channels are commanded by a specified
sequence of pulses and triggered by crankshaft angle events for each pulse, with respect to an assigned
Top Dead Center (TDC) reference value. The pulse sequence is configured via the
window. The TDC reference value is configured via the
tab of the
Engine Position Tracking Setup
window. Engine position tracking parameters are configured via the
Engine Position Tracking Setup
window for a variety of crank and cam signal patterns.
DIX_PowerSupplyEnable
Tip Strip: Enables internal boost power supply
Detail: When
ON
, the module internal boost power supply is enabled and will maintain the working voltage
specified by
OFF
, the module internal boost power supply is disabled. The actual boost
voltage is displayed in the
indicator within this window. For more information on the
module internal boost power supply, please see
DIX_InjectionEnable
Tip Strip: Enables all channels of module
Detail: When
ON
, the module injection control circuitry is enabled. When
OFF
, the module injection control
circuitry is disabled. This parameter does not generate any injection pulses, but only enables the driver
circuitry to operate when fuel commands are generated.
Summary of Contents for NI DIDS-2103
Page 11: ...NI DIDS 2100 Series User Manual National Instruments 11 3 2 Software...
Page 32: ...32 ni com NI DIDS 2100 Series User Manual...
Page 40: ...40 ni com NI DIDS 2100 Series User Manual 3 3 Hardware...
Page 44: ...44 ni com NI DIDS 2100 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 174: ...174 ni com NI DIDS 2100 Series User Manual Aux PWX 2 4 See above descriptions...
Page 210: ...210 ni com NI DIDS 2100 Series User Manual 12 Connecting Port Fuel Injectors to the PFI Driver...
Page 214: ...214 ni com NI DIDS 2100 Series User Manual 16 9066 RS 232 Serial Connector to TDK Power Supply...
Page 216: ...216 ni com NI DIDS 2100 Series User Manual 8 Important Information...
Page 223: ...NI DIDS 2100 Series User Manual National Instruments 223...