National Instruments Direct Injector Driver System Manual
© 2013 National Instruments. All rights reserved.
3.3.3.5 Analog Signals to NI 9215 Analog Input Module
The DI Driver System supports an optional NI 9215 four-channel analog input module. The analog inputs are
sampled at an interval of 15 milliseconds. The analog inputs are filtered and converted to engineering units via the
. The engineering values can be used as inputs to a variety of functions throughout the DI
Driver System, such as lookup tables and rail pressure control.
The analog input channels are capable of directly measuring differ/- 10V signals. Therefore, each channel
has a positive and negative screw terminal connection. A COM terminal is provided as a common mode reference
for all four (4) channels. Refer to the NI
Operating Instructions and Specifications for detailed connection
diagrams and specifications.