4.8.2 Table2D
A 2D lookup table control consists of a set of X and Y 1D input arrays and a matching Z 2D output array. The X
values correspond to the input parameter as specified in
the input parameter as specified in
. The 2D lookup table Z output is routed to the Flex
Control Parameters selected in
Table2D_X_FlexControlParameters
. The Flex Control Parameters are a list of many
controls from the various setup windows of the DI Driver System. When a Flex Control Parameter is selected here,
the value from the lookup table output will overwrite that parameter. The table is only active when it is enabled via
Enable Table2D_X
Tip Strip: Enables 2D Table
Detail: When
ON
the lookup table is enabled and the selected Flex Control Parameters will be overwritten by
the lookup table output.
Table2D_Xa_InputSelector
Tip Strip: Assigns signal source to the 2D lookup table X array
Detail: Drop-down selection control for selecting the input parameter for the X values of the lookup table. The
available parameters for selection are analog inputs, battery voltage, digital input parameters, cam phase,
engine speed, and user variables.