Detail: Set to
FAULT
upon the detection of a pattern-specific crank feature while the
not yet reached the expected value.
Encoder Patterns:
Indicates
FAULT
when an EncZ rising edge occurs before the expected number of Crank
teeth have been counted.
N-M Patterns:
Indicates
FAULT
when a gap occurs before the expected number of Crank teeth have been
counted.
N+1 Patterns:
Indicates
FAULT
when a Plus1 tooth occurs before the expected number of Crank teeth have
been counted.
The FAULT condition causes a loss of sync. Re-sync is not allowed until the flag is cleared by pressing the
MissedGapFlag
Tip Strip: Indicates that the crank gap was not detected when expected
Detail: This indicator only applies to
FAULT
when an excess number of crank teeth
are counted before the gap is detected. In other words, physical teeth are received at the location where
a gap is expected. This condition causes a loss of sync. Re-sync is not allowed until the flag is cleared by
pressing the
button.
MissedCamFlag
Tip Strip: Indicates that the
rising edge was not detected when expected
Detail: This indicator only applies to encoder patterns. Indicates
FAULT
when an excess number of crank
This condition causes a loss of sync. Re-sync is not allowed until the flag is cleared by pressing the
MissedPlus1Flag
Tip Strip: Indicates that the crank Plus1 pulse was not detected when expected
Detail: This indicator only applies to
. Indicates
FAULT
when an excess number of crank teeth
are counted before the Plus1 tooth is detected. In other words, evenly spaced teeth are received at the
location where a Plus1 tooth is expected. This condition causes a loss of sync. Re-sync is not allowed until
the flag is cleared by pressing the