This will cause SCM to search the network for a National Instruments RT controller, such as the
cRIO-9076
or
cRIO-9022
. If the DI Driver System controller is discovered, take note of the discovered IP address. The
Windows PC used to interface with the system must have a similar IP address and Subnet mask as the
system controller, but the IP address must be different in the last address number. The Subnet mask should
be 255.255.255.0. Refer to the
section to see how to change the IP address of
the Windows PC. The
Select RT System
dialog may be exited by selecting the
Cancel
button. The
Backup
Target
dialog may be exited by selecting the
Back
button. The
Real-Time System Backup
dialog may be
exited by selecting the
Exit
button.
4. Check the System Controller Ethernet Cable Connection