8
Function Code
Description
Example
215/205
Set/Query Gateway Telephone Number (Representative
Number)
216/206
Set/Query the extension number of Line 1.
217/207
109
Restoring factory default IP address configuration
A static IP address for WAN Port
IP
192.168.1.2
Mask
255.255.255.0
Gateway
192.168.1.254
409
Restoring factory default settings
509
Save settings
900
Setting IVR and the language used on the Web GUI
(1: English, 2: Traditional Chinese, 3: Simplified
Chinese)
209
Soft Upgrade
Recorded Voice File
Ÿ
The gateway allows users to record their incoming call greeting messages, when calling via FXO.
Ÿ
After entering IVR mode, dial 132. After hearing “Enter value”, record the incoming call greeting
message. Hang up the phone to finish recording.
Ÿ
After recording, to listen to the recorded message, press 131. Press 133 to save the message.