40
Operating the Meter
Spatial Averaging with the 8718B
The Model 8718B uses time to quickly make precise, spatially
averaged measurements. With the 8718B set for spatial
averaging, press the
F1
function key to start the timer. Pressing
the same key again stops the timer. During this interval of time,
the meter takes a large number of measurements. The results
are presented as both an average value and a peak value.
Effective measurement technique requires you to simply move
the probe slowly from toe-to-head while the timer is running.
Although this technique may not be specifically called out in a
particular exposure standard, it is technically sound and much
more accurate than averaging a series of measurements. It is
anticipated that future updates of the major standards will reflect
this automatic technique now that the survey equipment makes
it practical.
To make spatially averaged measurements ...
1. Access the menu system by pressing the function key
that corresponds to the legend below
MENU
on the
bottom line of the display.
2. Press the number
3
on the keypad to select
SPATIAL
from the
First Menu Screen
.
3. Press
F1 (ON)
.
4. The meter will automatically return to the measurement
screen with new options for the function keys. If you
had accessed the menu system from the
Opening
Menu Screen
(where the calibration dates are shown),
you will return to that screen.
5. Holding the meter in one hand and the probe in the
other, touch the head of the probe to the ground.
S P A T I A L
A V E R A G I N G
M O D E
I S
O N
O N
O F F
F1
F2
F3
F4
Summary of Contents for 8718B
Page 9: ...8 Operating the Meter...
Page 37: ...36 Operating the Meter...
Page 71: ...70 Operating the Meter...
Page 75: ...74 Operating the Meter...
Page 79: ...78 Operating the Meter...
Page 87: ...86 Operating the Meter...
Page 104: ...103 Chapter 18 User s Software Main Menu Screen...
Page 108: ...107 Chapter 18 User s Software Probe Installation Screen...
Page 112: ...111 Chapter 18 User s Software Logged Survey Data Screen...
Page 124: ...123 Appendix B Theory of Operation Model 8718B Functional Block Diagram...
Page 129: ...128 Appendices...
Page 133: ...132 Appendices...