10 Description of the object dictionary
If the value is set to "FFFFFFFF"
h
, monitoring is switched off, the "Target reached" bit in object 6041
h
(controlword) is never set.
Object description
Index
203D
h
Object name
Torque Window
Object Code
VARIABLE
Data type
UNSIGNED16
Savable
yes, category: application
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
0000
h
Firmware version
FIR-v1540
Change history
Firmware version FIR-v1614: "Savable" entry changed from "no" to
"yes, category: application".
203Eh Torque Window Time
Function
The current torque must be within the "Torque Window" (203D
) for this time (in milliseconds) for the
target torque to be considered having been met.
Object description
Index
203E
h
Object name
Torque Window Time
Object Code
VARIABLE
Data type
UNSIGNED16
Savable
yes, category: application
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
0000
h
Firmware version
FIR-v1540
Change history
Firmware version FIR-v1614: "Savable" entry changed from "no" to
"yes, category: application".
2050h Encoder Alignment
Function
This value specifies the offset between the index of the encoder and the electric field.
Version: 2.0.1 / FIR-v1650