![NANOTEC ELECTRONIC N5 Technical Manual Download Page 191](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153191.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
Name
Transmission Type
Data type
UNSIGNED8
Access
read / write
PDO mapping
no
Allowed values
Preset value
FF
h
Subindex
03
h
Name
Inhibit Time
Data type
UNSIGNED16
Access
read / write
PDO mapping
no
Allowed values
Preset value
0064
h
Subindex
04
h
Name
Compatibility Entry
Data type
UNSIGNED8
Access
read / write
PDO mapping
no
Allowed values
Preset value
00
h
Subindex
05
h
Name
Event Timer
Data type
UNSIGNED16
Access
read / write
PDO mapping
no
Allowed values
Preset value
0000
h
Description
Subindex 01
h
(COB-ID): The COB-ID is stored here.
Subindex 02
h
(transmission type): A number is stored in this subindex that defines the time at which
the received data become valid.
Subindex 3 (inhibit time): This can be used to set a time in milliseconds that must elapse after the
sending of a PDO before the PDO is sent another time. This time only applies for asynchronous PDOs.
Subindex 4 (compatibility entry): This subindex has no function and exists only for compatibility
reasons.
Subindex 5 (event timer): This time (in ms) can be used to trigger an Event which handles the copying
of the data and the sending of the PDO.
For details, see chapter on configuring the TX-PDO mapping.
Version: 2.0.1 / FIR-v1650
191