Technical Manual N5 (CANopen)
10 Description of the object dictionary
Access
read / write
PDO mapping
no
Allowed values
Preset value
01
h
Description
The subindices have the following function:
•
01
h
: This subindex is used to define how to respond in case of a communication error:
•
Value "00"
h
: The controller switches to the Pre-Operational state (if previously in the Operational
state).
•
Value "01"
h
: The controller does not change state.
•
Value "02"
h
: The controller switches to the Stopped state.
•
02
h
: This subindex is used to define how to respond to the remaining errors (except for
communication errors):
•
Value "00"
h
: The controller switches to the Pre-Operational state (if previously in the Operational
state).
•
Value "01"
h
: The controller does not change state.
•
Value "02"
h
: The controller switches to the Stopped state.
1400h Receive PDO 1 Communication Parameter
Function
Contains the communication parameters for the receiving-side mapping (RX-PDO) in object 1600
h
.
See chapter Process Data Object (PDO).
Object description
Index
1400
h
Object name
Receive PDO 1 Communication Parameter
Object Code
RECORD
Data type
PDO_COMMUNICATION_PARAMETER
Savable
yes, category: communication
Firmware version
FIR-v1426
Change history
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
02
h
Version: 2.0.1 / FIR-v1650