![NANOTEC ELECTRONIC N5 Technical Manual Download Page 317](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153317.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
Description
This object is calculated as thousandths of the torque, e.g., the value "500" means "50%" of the rated
torque; "1100" is equivalent to 110%. The rated torque corresponds to the rated current in object
203B
h
:01.
The target torque may not exceed the peak torque (proportional to the peak current in 2031
h
).
6074h Torque Demand
Function
Current torque set value requested by the ramp generator in tenths of a percent of the nominal torque
for the internal controller.
Object description
Index
6074
h
Object name
Torque Demand
Object Code
VARIABLE
Data type
INTEGER16
Savable
no
Access
read only
PDO mapping
TX-PDO
Allowed values
Preset value
0000
h
Firmware version
FIR-v1426
Change history
Description
This object is calculated as thousandths of the torque, e.g., the value "500" means "50%" of the rated
torque; "1100" is equivalent to 110%. The rated torque corresponds to the rated current in object
203B
h
:01.
The target torque may not exceed the peak torque (proportional to the peak current in 2031
h
).
6077h Torque Actual Value
Function
This object indicates the current torque value in tenths of a percent of the nominal torque for the
internal controller.
Object description
Index
6077
h
Object name
Torque Actual Value
Object Code
VARIABLE
Data type
INTEGER16
Savable
no
Access
read only
PDO mapping
TX-PDO
Version: 2.0.1 / FIR-v1650