![NANOTEC ELECTRONIC N5 Technical Manual Download Page 293](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153293.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
4014h Operating Conditions
Function
This object is used to read out the current environment values for the controller.
Object description
Index
4014
h
Object name
Operating Conditions
Object Code
ARRAY
Data type
INTEGER32
Savable
no
Access
read only
PDO mapping
no
Allowed values
Preset value
Firmware version
FIR-v1540
Change history
Firmware version FIR-v1650-B472161: "Access" table entry for
subindex 01 changed from "read/write" to "read only".
Firmware version FIR-v1650-B472161: "Access" table entry for
subindex 02 changed from "read/write" to "read only".
Firmware version FIR-v1650-B472161: "Name" entry changed from
"Temperature PCB [d?C]" to "Temperature PCB [Celsius * 10]".
Firmware version FIR-v1650-B472161: "Access" table entry for
subindex 03 changed from "read/write" to "read only".
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
03
h
Subindex
01
h
Name
Voltage UB Power [mV]
Data type
INTEGER32
Access
read only
PDO mapping
TX-PDO
Allowed values
Preset value
00000000
h
Subindex
02
h
Version: 2.0.1 / FIR-v1650