10 Description of the object dictionary
255 => FF
h
0 => 0
The corresponding adjustment value is then
FFFFFF00
h
.
2030h Pole Pair Count
Function
Contains the number of pole pairs of the connected motor.
Object description
Index
2030
h
Object name
Pole Pair Count
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: tuning
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000032
h
Firmware version
FIR-v1426
Change history
Firmware version FIR-v1540: "Savable" entry changed from "no" to
"yes, category: tuning".
2031h Maximum Current
Function
t monitoring is not active, the rms current specified in the motor data sheet is entered here in mA.
If closed loop mode is used or if I
t monitoring is activated, the maximum current value is specified
here in mA.
Within the controller, the entered value is always interpreted as the root mean square.
Object description
Index
2031
h
Object name
Maximum Current
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: tuning
Access
read / write
PDO mapping
no
Allowed values
Preset value
•
N5-1-2: 000003E8
h
•
N5-2-2: 00000708
h
Version: 2.0.1 / FIR-v1650