![NANOTEC ELECTRONIC N5 Technical Manual Download Page 276](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153276.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
•
Voltage input: x digits * 10 V / 1024 digits
•
Current input: x digits * 20 mA / 1024 digits
3221h Analogue Inputs Control
Function
With this object, an analog input can be switched from voltage measurement to current measurement.
Object description
Index
3221
h
Object name
Analogue Inputs Control
Object Code
VARIABLE
Data type
INTEGER32
Savable
yes, category: application
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000000
h
Firmware version
FIR-v1426
Change history
Description
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
AC2
AC1
In general: If a bit is set to the value "0", the analog input measures the voltage; if the bit is set to the
value "1", the current is measured.
AC1
Setting for analog input 1
AC2
Setting for analog input 2
3225h Analogue Inputs Switches
Function
This object contains either the adjusted CANopen nodeId of the rotary switch or the positions of the
DIP switches
Object description
Index
3225
h
Object name
Analogue Inputs Switches
Version: 2.0.1 / FIR-v1650
276