![NANOTEC ELECTRONIC N5 Technical Manual Download Page 297](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153297.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
6041h Statusword
Function
This object returns information about the status of the CiA 402 Power State Machine.
Object description
Index
6041
h
Object name
Statusword
Object Code
VARIABLE
Data type
UNSIGNED16
Savable
no
Access
read only
PDO mapping
TX-PDO
Allowed values
Preset value
0000
h
Firmware version
FIR-v1426
Change history
Description
Parts of the object are, with respect to function, dependent on the currently selected mode.
QS
VE
WARN SOD
SO
RTSO
FAULT OE
OMS [2]
CLA
REM SYNC
ILA
TARG
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RTSO (Ready To Switch On)
Value = "1": Controller is in the "Ready to switch on" state
SO (Switched On)
Value = "1": Controller is in the "Switched on" state
OE (Operation Enabled)
Value = "1": Controller is in the "Operation enabled" state
FAULT
Error occurred
VE (Voltage Enabled)
Voltage applied
QS (Quick Stop)
Value = "0": Controller is in the "Quick stop" state
SOD (Switched On Disabled)
Value = "1": Controller is in the "Switched on disabled" state
WARN (Warning)
Value = "1": Warning
Version: 2.0.1 / FIR-v1650
297