MP SERIES™ Battery Backup System for Traffic Signals: MP2000E System
Volume One: Operating Manual
Page 6-22
SENSE TYPE
Toggle between Generator (Generator
parameter) and Normal (Normal
parameters). This broadens the unit's
input parameters to accommodate the
fluctuations created by a generator or
noisy line.
BATT COMP
This adjusts the battery charging
temperature compensated voltage to -
2.5 / -3 / -4 / or -5 mV/°C/ Cell. Consult
the manufacture's specifications to find
out which setting is best suited for your
batteries. The factory default setting is -
3 mV / °C / Cell.
SET DATE/TIME
Set BBS date and time.
DAYLIGHT SAVING
TIME
Turns on and off daylight savings time
to adjust the internal clock.
PROGRAMMABLE
INPUT
Sets the function that is executed when
the programmable input is activated.
Figure 6:13: Settings Submenu (continued)