Rockhopper II series printers – Maintenance Manual
119
AP-74065, Rev. 1.2, 27/09/04
4.8.4. Replacing the transmission photosensor (wiper home position
and maintenance home position)
Step 1 :
Remove the transmission photosensor from the side plate R.
1 = Transmission photosensor (wiper origin side)
2 = Transmission photosensor (maintenance origin
side)
3 = Wiper origin cable assembly
4 = Maintenance origin cable assembly
5 = Side plate R
Step 2 :
Remove each origin cable assembly from the transmission photosensor.
Step 3 :
Remove the transmission photosensor.
Step 4 :
Apply the screw lock to the tab portions of the transmission photosensors to be installed.
Step 5 :
Reinstall all parts in the opposite order of the removal procedure.
Notes :
¾
When installing the origin cable assembly onto the transmission photosensor, be
careful to not confuse the connectors.
Wiper origin cable assembly (black): front
Maintenance origin cable assembly (white): rear
Summary of Contents for Rockhopper II 2H
Page 1: ...Maintenance Manual MUTOH EUROPE N V AP 74065 Rev 1 2 27 09 2004 ...
Page 3: ...Rockhopper II series printers Maintenance Manual 4 AP 74065 Rev 1 2 27 09 04 ...
Page 5: ...Rockhopper II series printers Maintenance Manual 6 AP 74065 Rev 1 2 27 09 04 ...
Page 7: ...Rockhopper II series printers Maintenance Manual 8 AP 74065 Rev 1 2 27 09 04 ...
Page 13: ...Rockhopper II series printers Maintenance Manual 14 AP 74065 Rev 1 2 27 09 04 ...
Page 29: ...Rockhopper II series printers Maintenance Manual 30 AP 74065 Rev 1 2 27 09 04 ...
Page 201: ...Rockhopper II series printers Maintenance Manual 202 AP 74065 Rev 1 2 27 09 04 ...
Page 255: ...Rockhopper II series printers Maintenance Manual 256 AP 74065 Rev 1 2 27 09 04 ...
Page 318: ...Rockhopper II series printers Maintenance Manual 319 AP 74065 Rev 1 2 27 09 04 ...