7.16.3. Power board.
RED/GREEN(revC) ON
OFF
D2
From rev C on, it will be
a green led
OK
NO +24V present
→
PS ok?
→
Power cable ok?
RED ON OFF
D1
110/220V indicator
Should be on in a 110V
grid.
Should be off in a 220V
grid.
ON OFF
RED
Heater is on
Heater is off
D23, 21,19,13,6,4
During
cold
start-up, the selftest will run.
All leds should go on, one at a time, for a short period.
After a
warm
start-up, the selftest will not run.
During
normal
operation
: leds can go on in a random manner.
7.16.4. Heater Elements
Resistance (
Ω
) 50”
64”
87”
A
2 x 48
2 x 32,3
2 x 24,2
B1/B2
2 x 97
2 x 65,5
2 x 44
C
2 x 48
2 x 32,3
2 x 22,5
D1/ D2
2 x 27
2 x 22,5
2 x 22,5
Thermal Sensor
10k 10k 10k
When checking the thermal sensors, also measure them with the chassis as a reference. If the resistance is
not infinite, the sensor has a short circuit, mostly due to a damaged cable.
If the resistance is infinite, the thermal fuse might be blown. Or in minor cases, check for bad connections at
heater elements and connector.
Summary of Contents for Rockhopper II 2H
Page 1: ...Maintenance Manual MUTOH EUROPE N V AP 74065 Rev 1 2 27 09 2004 ...
Page 3: ...Rockhopper II series printers Maintenance Manual 4 AP 74065 Rev 1 2 27 09 04 ...
Page 5: ...Rockhopper II series printers Maintenance Manual 6 AP 74065 Rev 1 2 27 09 04 ...
Page 7: ...Rockhopper II series printers Maintenance Manual 8 AP 74065 Rev 1 2 27 09 04 ...
Page 13: ...Rockhopper II series printers Maintenance Manual 14 AP 74065 Rev 1 2 27 09 04 ...
Page 29: ...Rockhopper II series printers Maintenance Manual 30 AP 74065 Rev 1 2 27 09 04 ...
Page 201: ...Rockhopper II series printers Maintenance Manual 202 AP 74065 Rev 1 2 27 09 04 ...
Page 255: ...Rockhopper II series printers Maintenance Manual 256 AP 74065 Rev 1 2 27 09 04 ...
Page 318: ...Rockhopper II series printers Maintenance Manual 319 AP 74065 Rev 1 2 27 09 04 ...