15. Turn unit OFF and unplug.
O F F
16. Locate the dispense valve mounting plate in the top
center of the dispensing area. Remove the four (4)
outer screws that secure the mounting plate in place.
,
CAUTION
Using too much force while pulling down on the plastic mounting
plate could cause damage to the plate.
A. Pull gently down on the mounting plate until the
product tubing can be accessed. With the tubing
now accessible pull down on the tubing lowering
the dispense manifold as far down as possible.
Now locate the tubing inside of the refrigerated
cabinet.
B. The tubing is towards the upper right rear inside
of the cabinet and is separated by the chase that
runs upwards towards the dispensing area. Push
the tubing upwards as far as possible. Return to the
dispense area and pull the tubing downwards as
far as possible.
C. Return to the inside of the cabinet and push the
tubing upwards as far as possible.
D. Repeat the pulling of the tubing downwards in the
dispense area and the pushing up of the tubing
inside of the cabinet until the top of the dispensing
plate is easily accessible.
17. Using a Phillips head screw driver remove the two (2)
screws from the metal mounting plate that secures a
block of three (3) LMS valves to the dispensing valve
mounting plate.
NOTE: The tubing is numbered and will need to be returned
to the same position within the dispensing mounting plate
following the replacement of the LMS valves. Tubing is
positioned 1-8 in a counter clockwise manner with Water
being the 9th tube.
18. Remove the remaining two (2) blocks of three (3) valves
from the dispensing mounting plate.
19. Wash, rinse, and sanitize the dispensing mounting
plate. Using Oetiker pliers cut and remove the existing
Oetiker clamps that secure the product tubing to the
LMS valve.
20. Use the new 15.7 Oetiker clamps to replace the LMS
valves. It is best to replace a block of three (3) valves
at a time. Place the 15.7 Oetiker clamp on and up the
product tubing, insert the new LMS valve through the
metal plate and into the product tubing, crimp the 15.7
Oetiker clamp securing the product tubing to the LMS
valve body.
21. Return each block of three (3) LMS valves to the
dispensing mounting plate.