15. Turn unit OFF and unplug.

O F F

16. Locate the dispense valve mounting plate in the top 

center of the dispensing area. Remove the four (4) 

outer screws that secure the mounting plate in place.

,

CAUTION

Using too much force while pulling down on the plastic mounting 

plate could cause damage to the plate.

A.  Pull gently down on the mounting plate until the 

product tubing can be accessed. With the tubing 

now accessible pull down on the tubing lowering 

the dispense manifold as far down as possible. 

Now locate the tubing inside of the refrigerated 

cabinet.

B.  The tubing is towards the upper right rear inside 

of the cabinet and is separated by the chase that 

runs upwards towards the dispensing area. Push 

the tubing upwards as far as possible. Return to the 

dispense area and pull the tubing downwards as 

far as possible. 

C.  Return to the inside of the cabinet and push the 

tubing upwards as far as possible. 

D.  Repeat the pulling of the tubing downwards in the 

dispense area and the pushing up of the tubing 

inside of the cabinet until the top of the dispensing 

plate is easily accessible.

17. Using a Phillips head screw driver remove the two (2) 

screws from the metal mounting plate that secures a 

block of three (3) LMS valves to the dispensing valve 

mounting plate.

NOTE: The tubing is numbered and will need to be returned 

to the same position within the dispensing mounting plate 

following the replacement of the LMS valves. Tubing is 

positioned 1-8 in a counter clockwise manner with Water 

being the 9th tube.

18. Remove the remaining two (2) blocks of three (3) valves 

from the dispensing mounting plate.

19. Wash, rinse, and sanitize the dispensing mounting 

plate. Using Oetiker pliers cut and remove the existing 

Oetiker clamps that secure the product tubing to the 

LMS valve.

20. Use the new 15.7 Oetiker clamps to replace the LMS 

valves. It is best to replace a block of three (3) valves 

at a time. Place the 15.7 Oetiker clamp on and up the 

product tubing, insert the new LMS valve through the 

metal plate and into the product tubing, crimp the 15.7 

Oetiker clamp securing the product tubing to the LMS 

valve body. 

21. Return each block of three (3) LMS valves to the 

dispensing mounting plate.

Front of Unit

Summary of Contents for BIC MA-8-2

Page 1: ...IPTION PART NUMBER 1 SWITCH REED RINSE AREA MOD 2160033 1 SWITCH REED RINSE AREA GRAY 2162748 5 FUSE 5A MIXER BOARD 2193015 1 SWITCH SNAP ACTION MINI BLEN HM 2194807 1 BOARD SRB BIC GEN2 2195346 2 CONTROL BLENDER BIC HSM 2195363 1 CONTROL 7 IN UI BIC 000 BIC 01F9 S 1 RELAY 24DC COIL DPDT 2196069 2 FUSE 4A DC HARNESS 2198785 1 PUMP FLOJET NSF NO ASO 3239675 1 MIXER MTR 6MM 120V 50 60 GEN3 SW 323982...

Page 2: ...rewdriver or pair of needle nose pliers remove the O rings from each blender grate and discard 7 Replace with new O rings over the tip on both grates 8 Wash rinse and sanitize the blender and dispense grates 9 Prepare a five 5 gallon bucket with luke warm tap water no hotter than 105 F 40 5 C and cleaning solution Clean all eight 8 product fittings and connect the cleaning manifold 10 Position the...

Page 3: ...ea and the pushing up of the tubing inside of the cabinet until the top of the dispensing plate is easily accessible 17 Using a Phillips head screw driver remove the two 2 screws from the metal mounting plate that secures a block of three 3 LMS valves to the dispensing valve mounting plate NOTE The tubing is numbered and will need to be returned to the same position within the dispensing mounting ...

Page 4: ... using caution not to damage the micro switch push rod Use caution not to lose any of the three 3 ice bin grommets attached to the base of the ice bin bowl 26 Wash rinse and sanitize the condensate bowl 27 Carefully pour beverage drain cleaner down the ice condensate bowl drain opening 28 Remove the two 2 screws that secure the shaver blade and shims to the ice bin and ice chute cartridge 29 Insta...

Page 5: ... Once the shaver belt is replaced the motor will be returned or very near this same position when tight 38 Locate the four 4 hex head bolts that secure the shaver motor to the motor mounting bracket A Completely remove one of the bolts that secure the Hall Effect sensor mounting bracket to the motor mounting bracket Loosen the remaining three 3 hex head bolts B Swing the Hall Effect mounting brack...

Page 6: ...and CO2 supply lines and pressure observe for any leaks 54 Power the unit ON using the ON OFF switch located on the upper left side of the unit next to the USB port 55 Connect drain and plug in unit to outlet 56 Verify the water and CO2 pressure regulators are set to 35 psi dynamic and adjust if necessary A The regulators are located on the upper left side of the unit NOTE To achieve a dynamic pre...

Page 7: ...lect the Configure Slots Icon Select Slot Flavor Select the slot requiring reassignment Select Unassign Flavor and then select the GREEN Check Select the newly Unassigned Slot and select the correct flavor assignment Select the Return Arrow three 3 times to return to the main easyToUCH screen Select product Inventory Icon Select the reassigned flavor and follow the steps for replacing a product ba...

Page 8: ...ds must be entered to reset the yearly maintenance reminder even though the shafts have NOT been changed Select the MANAGER MENU Select A for the password Select the GREEN check Select the Down Arrow and select SERVICE Select A for the password Select the GREEN check Arrow DOWN and select PLANNED MAINTENANCE Select MIXER MAINTENANCE PERFORMED A 4 0 2 and before Enter SILENCE for password Select th...

Page 9: ...ge5 ReplacetheCO2andWatersupplylineO rings Step43 44onpage6 Cleanthecondensercoil Step45page6 Cleanthecondensatepan Step46page6 Cleanthecondensatedrainline Step47page6 Pourhotwaterdowndrainopeningsoftheicebin rightblendchamber dispense area andleftblendchamber Step49page6 Workthedrainsbyhandsqueezingoutanybuildup Step51 52onpage6 Connectwater CO2 drain andpowercord Step55page6 Reardrainlineconnect...