43. Remove and replace the O-rings on both the water and 

CO2 supply lines.

44. Add food grade lube to the O-rings before 

reconnecting the water and CO2 supply lines.

45. Use a soft bristle brush to remove the dust, dirt and 

debris from the condenser coil.

46. Clean the condensate drain pan with Wet/Dry Shop 

Vacuum.

 

47. Locate the condensate drain line. 

A.  Clean the condensate drain line with Wet/Dry Shop 

Vacuum by applying suction to the outlet of the 

drain line.

48. Remove both the left and  right side panels.
49. Slowly pour hot tap water down the left side and right 

side blend chamber drains, rinse area drain, and the ice 

bin drain. 

50. Check unit to make sure it is level from front to back 

and side to side. 

51. Locate the three (3) drain tubes within upper frame of 

the unit.

A.  Beginning at the discharge of each drain outlet 

squeeze the tubing from front to back dislodging 

any buildup within the tubing. 

B.  Snake each drain with a 6 ft (1.8m) piece of ¼” I.D. 

x 3/8 “ O.D. clear flexible tubing. Verify water is 

draining sufficiently out of the blend chambers.   

Or use a Wet/Dry Shop Vacuum to remove any 

debris from the drain lines.

52. Repeat previous step until each drain line runs clear.
53. Reconnect incoming water and CO

2

 supply lines and 

pressure, observe for any leaks.

54. Power the unit ON using the ON/OFF switch located on 

the upper left side of the unit next to the USB port.

55. Connect drain and plug in unit to outlet. 
56. Verify the water and CO2 pressure regulators are set to 

35 psi dynamic and adjust if necessary.

 

A.  The regulators are located on the upper left side of 

the unit. 

NOTE: To achieve a dynamic pressure setting for the water 

a water solenoid must be activated. To achieve a dynamic 

pressure setting for the CO2 one of the product solenoids 

must be activated. 

B.  Follow the next steps from the easyToUCH screen 

to activate a water solenoid and/or a product 

solenoid: 

 

Select the MANAGER MENU Icon

 

Select “A” for the password

 

Select the GREEN check

 

Arrow DOWN and Select Service

 

Select “A” for the password

 

Select the GREEN check

 

Select OUTPUTS

 

Activate any of the eight (8) flavor solenoids by 

touching the GREEN OFF opposite the selected 

solenoid and adjust the CO2 regulator to 35 psi 

dynamic

 

Turn OFF selected flavor solenoid by touching thr 

RED ON opposite the selected solenoid.

 

Arrow DOWN then select either the WATER, LEFT 

RINSE, or RIGHT RINSE and adjust the water 

regulator to 35 psi dynamic

 

Turn OFF selected water dispense option

 

Arrow back three (3) times to return to the main 

easyToUCH screen.  

NOTE: To increase the pressure lift the knob at the top of 

the regulator and turn clockwise. To decrease the pressure 

lift the knob at the top and turn counter clockwise.

Summary of Contents for BIC MA-8-2

Page 1: ...IPTION PART NUMBER 1 SWITCH REED RINSE AREA MOD 2160033 1 SWITCH REED RINSE AREA GRAY 2162748 5 FUSE 5A MIXER BOARD 2193015 1 SWITCH SNAP ACTION MINI BLEN HM 2194807 1 BOARD SRB BIC GEN2 2195346 2 CONTROL BLENDER BIC HSM 2195363 1 CONTROL 7 IN UI BIC 000 BIC 01F9 S 1 RELAY 24DC COIL DPDT 2196069 2 FUSE 4A DC HARNESS 2198785 1 PUMP FLOJET NSF NO ASO 3239675 1 MIXER MTR 6MM 120V 50 60 GEN3 SW 323982...

Page 2: ...rewdriver or pair of needle nose pliers remove the O rings from each blender grate and discard 7 Replace with new O rings over the tip on both grates 8 Wash rinse and sanitize the blender and dispense grates 9 Prepare a five 5 gallon bucket with luke warm tap water no hotter than 105 F 40 5 C and cleaning solution Clean all eight 8 product fittings and connect the cleaning manifold 10 Position the...

Page 3: ...ea and the pushing up of the tubing inside of the cabinet until the top of the dispensing plate is easily accessible 17 Using a Phillips head screw driver remove the two 2 screws from the metal mounting plate that secures a block of three 3 LMS valves to the dispensing valve mounting plate NOTE The tubing is numbered and will need to be returned to the same position within the dispensing mounting ...

Page 4: ... using caution not to damage the micro switch push rod Use caution not to lose any of the three 3 ice bin grommets attached to the base of the ice bin bowl 26 Wash rinse and sanitize the condensate bowl 27 Carefully pour beverage drain cleaner down the ice condensate bowl drain opening 28 Remove the two 2 screws that secure the shaver blade and shims to the ice bin and ice chute cartridge 29 Insta...

Page 5: ... Once the shaver belt is replaced the motor will be returned or very near this same position when tight 38 Locate the four 4 hex head bolts that secure the shaver motor to the motor mounting bracket A Completely remove one of the bolts that secure the Hall Effect sensor mounting bracket to the motor mounting bracket Loosen the remaining three 3 hex head bolts B Swing the Hall Effect mounting brack...

Page 6: ...and CO2 supply lines and pressure observe for any leaks 54 Power the unit ON using the ON OFF switch located on the upper left side of the unit next to the USB port 55 Connect drain and plug in unit to outlet 56 Verify the water and CO2 pressure regulators are set to 35 psi dynamic and adjust if necessary A The regulators are located on the upper left side of the unit NOTE To achieve a dynamic pre...

Page 7: ...lect the Configure Slots Icon Select Slot Flavor Select the slot requiring reassignment Select Unassign Flavor and then select the GREEN Check Select the newly Unassigned Slot and select the correct flavor assignment Select the Return Arrow three 3 times to return to the main easyToUCH screen Select product Inventory Icon Select the reassigned flavor and follow the steps for replacing a product ba...

Page 8: ...ds must be entered to reset the yearly maintenance reminder even though the shafts have NOT been changed Select the MANAGER MENU Select A for the password Select the GREEN check Select the Down Arrow and select SERVICE Select A for the password Select the GREEN check Arrow DOWN and select PLANNED MAINTENANCE Select MIXER MAINTENANCE PERFORMED A 4 0 2 and before Enter SILENCE for password Select th...

Page 9: ...ge5 ReplacetheCO2andWatersupplylineO rings Step43 44onpage6 Cleanthecondensercoil Step45page6 Cleanthecondensatepan Step46page6 Cleanthecondensatedrainline Step47page6 Pourhotwaterdowndrainopeningsoftheicebin rightblendchamber dispense area andleftblendchamber Step49page6 Workthedrainsbyhandsqueezingoutanybuildup Step51 52onpage6 Connectwater CO2 drain andpowercord Step55page6 Reardrainlineconnect...