background image

 

5 of 9

 

Document Number: 020009017  May 12, 2022

Subject: BIC Tune Up 

34. Reinstall the ice bin to the condensate bowl using the 

four (4) screws.

NOTE: Use caution not to damage the push rod.

35. Remove the two (2) Phillips head screws that secure the 

rear panel to the units frame and remove the rear panel.

36. Locate the mounting bracket that houses the power 

supply, relays and SRB. Remove the two (2) screws that 

secure the mounting bracket to the units frame.

A.  Slightly lift the bracket releasing the right side 

hinge then carefully lower the bracket down 

towards the lower refrigerated cabinet.

37. Mark the position of the shaver motor as currently 

positioned within the motor mounting bracket.

NOTE: Once the shaver belt is replaced the motor will be 

returned or very near this same position when tight. 

38. Locate the four (4) hex head bolts that secure the 

shaver motor to the motor mounting bracket.

A.  Completely remove one of the bolts that secure 

the Hall Effect sensor mounting bracket to the 

motor mounting bracket. Loosen the remaining 

three (3) hex head bolts. 

B.  Swing the Hall Effect mounting bracket to the side 

allowing room for easy removal of the shaver belt. 

39. Remove the existing shaver belt.
40. Replace the provided shaver belt reversing the actions 

in Step 37. Tighten the belt by pulling back on the 

motor before completely tightening the hex head bolts. 

Motor should be positioned at or near the previous 

placed reference mark.

41. Confirm Hall Effect Sensor is 1/16 of an inch back from 

the edge of the bracket and in good condition.

42. Disconnect the water and CO2 supply lines.

Summary of Contents for BIC MA-8-2

Page 1: ...IPTION PART NUMBER 1 SWITCH REED RINSE AREA MOD 2160033 1 SWITCH REED RINSE AREA GRAY 2162748 5 FUSE 5A MIXER BOARD 2193015 1 SWITCH SNAP ACTION MINI BLEN HM 2194807 1 BOARD SRB BIC GEN2 2195346 2 CONTROL BLENDER BIC HSM 2195363 1 CONTROL 7 IN UI BIC 000 BIC 01F9 S 1 RELAY 24DC COIL DPDT 2196069 2 FUSE 4A DC HARNESS 2198785 1 PUMP FLOJET NSF NO ASO 3239675 1 MIXER MTR 6MM 120V 50 60 GEN3 SW 323982...

Page 2: ...rewdriver or pair of needle nose pliers remove the O rings from each blender grate and discard 7 Replace with new O rings over the tip on both grates 8 Wash rinse and sanitize the blender and dispense grates 9 Prepare a five 5 gallon bucket with luke warm tap water no hotter than 105 F 40 5 C and cleaning solution Clean all eight 8 product fittings and connect the cleaning manifold 10 Position the...

Page 3: ...ea and the pushing up of the tubing inside of the cabinet until the top of the dispensing plate is easily accessible 17 Using a Phillips head screw driver remove the two 2 screws from the metal mounting plate that secures a block of three 3 LMS valves to the dispensing valve mounting plate NOTE The tubing is numbered and will need to be returned to the same position within the dispensing mounting ...

Page 4: ... using caution not to damage the micro switch push rod Use caution not to lose any of the three 3 ice bin grommets attached to the base of the ice bin bowl 26 Wash rinse and sanitize the condensate bowl 27 Carefully pour beverage drain cleaner down the ice condensate bowl drain opening 28 Remove the two 2 screws that secure the shaver blade and shims to the ice bin and ice chute cartridge 29 Insta...

Page 5: ... Once the shaver belt is replaced the motor will be returned or very near this same position when tight 38 Locate the four 4 hex head bolts that secure the shaver motor to the motor mounting bracket A Completely remove one of the bolts that secure the Hall Effect sensor mounting bracket to the motor mounting bracket Loosen the remaining three 3 hex head bolts B Swing the Hall Effect mounting brack...

Page 6: ...and CO2 supply lines and pressure observe for any leaks 54 Power the unit ON using the ON OFF switch located on the upper left side of the unit next to the USB port 55 Connect drain and plug in unit to outlet 56 Verify the water and CO2 pressure regulators are set to 35 psi dynamic and adjust if necessary A The regulators are located on the upper left side of the unit NOTE To achieve a dynamic pre...

Page 7: ...lect the Configure Slots Icon Select Slot Flavor Select the slot requiring reassignment Select Unassign Flavor and then select the GREEN Check Select the newly Unassigned Slot and select the correct flavor assignment Select the Return Arrow three 3 times to return to the main easyToUCH screen Select product Inventory Icon Select the reassigned flavor and follow the steps for replacing a product ba...

Page 8: ...ds must be entered to reset the yearly maintenance reminder even though the shafts have NOT been changed Select the MANAGER MENU Select A for the password Select the GREEN check Select the Down Arrow and select SERVICE Select A for the password Select the GREEN check Arrow DOWN and select PLANNED MAINTENANCE Select MIXER MAINTENANCE PERFORMED A 4 0 2 and before Enter SILENCE for password Select th...

Page 9: ...ge5 ReplacetheCO2andWatersupplylineO rings Step43 44onpage6 Cleanthecondensercoil Step45page6 Cleanthecondensatepan Step46page6 Cleanthecondensatedrainline Step47page6 Pourhotwaterdowndrainopeningsoftheicebin rightblendchamber dispense area andleftblendchamber Step49page6 Workthedrainsbyhandsqueezingoutanybuildup Step51 52onpage6 Connectwater CO2 drain andpowercord Step55page6 Reardrainlineconnect...

Reviews: