4 of 9
Document Number: 020009017 May 12, 2022
Subject: BIC Tune Up
NOTE: The tubing orientation is 1-9 in a counter clockwise
manner as shown.
22. Reposition the dispensing mounting plate to the top of
the dispensing area and secure with the four (4) outer
screws.
A. Reverse actions in Step 16 pulling the tubing
downwards within the refrigerated cabinet and
pushing the tubing upwards in the dispensing area
towards the inside of the tubing chase.
,
CAUTION
Ice shaver blade is sharp on both edges. Wear cut resistant gloves
when handling.
23. Remove the ice assist bar, ice bin lid, ice shelf, paddle
nut, and shaver wheel.
24. Using a Phillips head screwdriver remove the four (4)
screws that secure the ice bin to the condensate bowl.
,
CAUTION
Be careful not to damage push rod when removing the ice bin.
Push rod should not be bent or have pressure applied to it.
25. Carefully remove the ice bin using caution not to
damage the micro switch push rod. Use caution not to
lose any of the three (3) ice bin grommets attached to
the base of the ice bin bowl.
26. Wash, rinse and sanitize the condensate bowl.
27. Carefully pour beverage drain cleaner down the ice
condensate bowl drain opening.
28. Remove the two (2) screws that secure the shaver blade
and shims to the ice bin and ice chute cartridge.
29. Install new blade using old shims.
NOTE: Shim configuration is important. Shim alignment
should be two (2) .056 thick shims and one (1) #7 thin shim.
30. Wash, rinse and sanitize the ice bin.
31. Remove the shaver gasket. You may find the gasket
adhered to the bottom of the ice bin or the top of the
dispense area cover.
32. Clean all surfaces where the previous gasket made
contact.
33. Dry the contact points for the shaver gasket. Adhere
the new shaver gasket to the top of the dispense area
cover.
NOTE: Ensure the gasket does not block any of the ice chute
opening.
,
CAUTION
Be careful not to damage push rod when reinstalling the ice bin.
Push rod should be carefully inserted into bottom of ice bin