57. Once the 35 psi dynamic setting has been achieved 

push the knob back to the downward position and turn 

OFF the water solenoid and/or the product solenoid.

58. Re-install all exterior panels and move unit into place.  

Verify drain line is connected correctly.

59. From the easyToUCH screen select the hand icon. Then 

select the Zone 2 icon and follow the instructions to 

complete the weekly cleaning. 

NOTE: The manager will need to be informed that the 

weekly cleaner timer was reset following the Zone 2 

cleaning. To get the weekly cleaning back to the stores 

normal cleaning schedule they will need to perform the 

weekly cleaning on the normal scheduled day. 

60. Retrieve the product from the walk in cooler and return 

it to the assigned slot position within the BIC unit. 
A.  Verify flavor slot assignments are in accordance 

with corporate direction. If the product 

assignments are not in accordance they must be 

reassigned.

Strawberry 

Banana

Mocha

Caramel

Not 

Assigned

Slushy

Not Assigned

or Seasonal

Mango 

Pineapple

Yogurt

B.  If reassignment is required follow the next steps 

from the easyToUCH screen:

 

Select the MANAGER MENU Icon

 

Select “A” for the password

 

Select the GREEN check

 

Select the Configure Slots Icon

 

Select Slot Flavor

 

Select the slot requiring reassignment

 

Select Unassign Flavor and then select the GREEN 

Check

 

Select the newly Unassigned Slot and select the 

correct flavor assignment

 

Select the Return Arrow three (3) times to return to 

the main easyToUCH screen

 

Select product Inventory Icon

 

Select the reassigned flavor and follow the steps for 

replacing a product bag.  

 

Follow the same procedures for each reassigned 

product.

CALIBRATION & SETTINGS

61. Fill the ice bin with ice.
62. Allow cabinet and nozzle temperatures to drop below 

39°F. Cabinet temperature will need to be 39°F or below 

before beginning next step.

63. Perform FACTORY RESET.

 

Select MANAGER Menu.  

 

Select “A” for the password

 

Select the GREEN check

 

Arrow DOWN one (1) time

 

Select SERVICE

 

Select “A” for the password

 

Select the GREEN check

 

Arrow DOWN one (1) time

 

Select FACTORY RESET

 

Select the GREEN check

 

Calibrations have been reset

 

Arrow UP or press BACK arrow to return to main screen

64. Confirm the “CONFIGURE YOGURT SMALL DISPENSE” is 

set to zero (0) from the easyToUCH screen:

 

Select the MANAGER MENU

 

Select “A” for the password

 

Select the GREEN check

 

Arrow DOWN one (1) time

 

Select SERVICE

 

Select “A” for the password

 

Select the GREEN check

 

Arrow DOWN two (2) times

 

Select CONFIGURE YOGURT SMALL DISPENSE

 

Confirm SLOT NUMBER is zero (0). 

 

If SLOT NUMBER is not zero (0), select the box to the 

left> Enter 0> Select the GREEN check> Arrow back 

twice> and Save if prompted. 

Summary of Contents for BIC MA-8-2

Page 1: ...IPTION PART NUMBER 1 SWITCH REED RINSE AREA MOD 2160033 1 SWITCH REED RINSE AREA GRAY 2162748 5 FUSE 5A MIXER BOARD 2193015 1 SWITCH SNAP ACTION MINI BLEN HM 2194807 1 BOARD SRB BIC GEN2 2195346 2 CONTROL BLENDER BIC HSM 2195363 1 CONTROL 7 IN UI BIC 000 BIC 01F9 S 1 RELAY 24DC COIL DPDT 2196069 2 FUSE 4A DC HARNESS 2198785 1 PUMP FLOJET NSF NO ASO 3239675 1 MIXER MTR 6MM 120V 50 60 GEN3 SW 323982...

Page 2: ...rewdriver or pair of needle nose pliers remove the O rings from each blender grate and discard 7 Replace with new O rings over the tip on both grates 8 Wash rinse and sanitize the blender and dispense grates 9 Prepare a five 5 gallon bucket with luke warm tap water no hotter than 105 F 40 5 C and cleaning solution Clean all eight 8 product fittings and connect the cleaning manifold 10 Position the...

Page 3: ...ea and the pushing up of the tubing inside of the cabinet until the top of the dispensing plate is easily accessible 17 Using a Phillips head screw driver remove the two 2 screws from the metal mounting plate that secures a block of three 3 LMS valves to the dispensing valve mounting plate NOTE The tubing is numbered and will need to be returned to the same position within the dispensing mounting ...

Page 4: ... using caution not to damage the micro switch push rod Use caution not to lose any of the three 3 ice bin grommets attached to the base of the ice bin bowl 26 Wash rinse and sanitize the condensate bowl 27 Carefully pour beverage drain cleaner down the ice condensate bowl drain opening 28 Remove the two 2 screws that secure the shaver blade and shims to the ice bin and ice chute cartridge 29 Insta...

Page 5: ... Once the shaver belt is replaced the motor will be returned or very near this same position when tight 38 Locate the four 4 hex head bolts that secure the shaver motor to the motor mounting bracket A Completely remove one of the bolts that secure the Hall Effect sensor mounting bracket to the motor mounting bracket Loosen the remaining three 3 hex head bolts B Swing the Hall Effect mounting brack...

Page 6: ...and CO2 supply lines and pressure observe for any leaks 54 Power the unit ON using the ON OFF switch located on the upper left side of the unit next to the USB port 55 Connect drain and plug in unit to outlet 56 Verify the water and CO2 pressure regulators are set to 35 psi dynamic and adjust if necessary A The regulators are located on the upper left side of the unit NOTE To achieve a dynamic pre...

Page 7: ...lect the Configure Slots Icon Select Slot Flavor Select the slot requiring reassignment Select Unassign Flavor and then select the GREEN Check Select the newly Unassigned Slot and select the correct flavor assignment Select the Return Arrow three 3 times to return to the main easyToUCH screen Select product Inventory Icon Select the reassigned flavor and follow the steps for replacing a product ba...

Page 8: ...ds must be entered to reset the yearly maintenance reminder even though the shafts have NOT been changed Select the MANAGER MENU Select A for the password Select the GREEN check Select the Down Arrow and select SERVICE Select A for the password Select the GREEN check Arrow DOWN and select PLANNED MAINTENANCE Select MIXER MAINTENANCE PERFORMED A 4 0 2 and before Enter SILENCE for password Select th...

Page 9: ...ge5 ReplacetheCO2andWatersupplylineO rings Step43 44onpage6 Cleanthecondensercoil Step45page6 Cleanthecondensatepan Step46page6 Cleanthecondensatedrainline Step47page6 Pourhotwaterdowndrainopeningsoftheicebin rightblendchamber dispense area andleftblendchamber Step49page6 Workthedrainsbyhandsqueezingoutanybuildup Step51 52onpage6 Connectwater CO2 drain andpowercord Step55page6 Reardrainlineconnect...

Reviews: