"Sensors" menu - configuration and calibration
Carrying out 100 litre calibration
26
V2.20161017
30252060-02-EN
⇨
From this screen you can access all the other screens you need to configure the sensor.
Carrying out 100 litre calibration
WARNING
Danger of poisoning from spray liquid residues
When configuring the tank:
◦ Always use clean water.
NOTICE
Inaccurate calibration due to incorrect fill volume
If the configuration is wrong the fill level cannot be measured accurately. This makes all calculations
imprecise.
When calibrating the tank:
◦ Use a flow meter or a weighbridge.
The purpose of the 100 litre calibration is:
▪ To equalise manufacturing tolerances
▪ To correct changes in accuracy over time.
1.
Open the "Sensors" menu.
2.
Press:
>
⇨
The following screen will appear:
3.
Empty the tank completely.
4.
Press:
⇨
The following screen will appear:
5.
Add exactly 100 litres of water to the tank.
8.2
Procedure