"Sensors" menu - configuration and calibration
Opening the "Sensors" menu
8
30252060-02-EN
V2.20161017
25
"Sensors" menu - configuration and calibration
You must configure and calibrate the sensor before you use TANK-Control II for the first time.
Who configures what?
Configuration
Purpose
Who does it?
When?
100 litre calibration
Equalise installation
tolerances
User
Prior to initial
startup.
Basic initialisation
Recognise the
sensor
Installer
After installation of
the sensor.
Tank size
Prepare tank for
calibration
Field sprayer manufacturer
Before calibration.
Calibration
Determine sensor
values
Field sprayer manufacturer
After the first
sensor has been
installed on a new
model of field
sprayer.
Sensor sensitivity
Set the sensitivity of
the sensor
User
If the sensor
response to water
movement is too
sensitive.
NOTICE
During calibration the tank must be filled manually. TANK-Control II cannot control filling pumps, ball
valves, etc. during calibration.
Opening the "Sensors" menu
To open the "Sensors" menu:
1.
Start the control unit.
⇨
The start screen appears.
2.
Select the "Sensors" line.
3.
Press this key:
⇨
The following screen will appear:
8
8.1
Procedure