11
Configuring external devices
Configuring a ball valve
56
V2.20161017
30252060-02-EN
⇨
If the filling pump has a PWM actuator and you have activated the selection field, the screen
changes:
8.
Press
or
to set the PWM frequency. You will find the correct PWM frequency in
the technical specifications for the filling pump. In this case, the PWM frequency is 500Hz.
9.
Select the relevant percentage to change the maximum or minimum filling pump speed.
10.
Press this key:
⇨
The data input screen appears.
11.
Enter the percentage required.
12.
Press this key:
13.
Repeat steps 9 to 12 for the other percentage.
14.
Press the
key to save the settings.
⇨
TANK-Control II switches off.
15.
Restart TANK-Control II to use the new settings.
Configuring a ball valve
1.
Open the "Tank Control II" menu.
2.
Press:
>
3.
Enter the password (14232314).
4.
Press
until the following screen appears:
5.
Press the
key to activate the selection field
if a ball valve is used.
11.2
Procedure