Adjusting valve clearance
1.
Release locknut (1).
2.
Insert feeler gage between valve bridge and
rocker arm.
3.
Using offset screwdriver, set adjusting
screw (2) such that specified valve clear-
ance is set.
4.
Feeler gage must just pass through the
gap.
5.
Tighten locknut (1) with torque wrench to the specified tightening torque, holding the adjusting
screw (2) to prevent it from turning.
Name
Size
Type
Lubricant
Value/Standard
Locknut
M16
Tightening torque
(Engine oil)
90 Nm +9 Nm
6.
Replace or rectify adjusting screws and/or locknuts which do not move freely.
7.
Check valve clearance.
Final steps
1.
Remove barring gear (→ Page 137).
2.
Install cylinder head cover (→ Page 158).
MS150033/05E 2013-10
| Task Description | 155