1.4520.640 – MIC5 ISE Secon Short Circuit Cyl 11
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 11 in ignition
sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.641 – MIC5 ISE Secon Short Circuit Cyl 12
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 12 in ignition
sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.642 – MIC5 ISE Secon Short Circuit Cyl 13
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 13 in ignition
sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.643 – MIC5 ISE Secon Short Circuit Cyl 14
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 14 in ignition
sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.644 – MIC5 ISE Secon Short Circuit Cyl 15
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 15 in ignition
sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
1.4520.645 – MIC5 ISE Secon Short Circuit Cyl 16
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 16 in ignition
sequence.
1. Check ignition lead, connector and igniter.
2. Check ignition coil.
114 | Troubleshooting | MS150116/04E 2018-04
TIM-ID: 0000038611 - 006